Origin Standard

GB/T 23800-2009 Determination of thermal stability of organic heat transfer fluids

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key points of answer
Which foreign standard is adopted by this standard? Modified adoption of DIN 51528:1998 "Determination of thermal stability of unused heat transfer fluids" (English version)
Which organic heat transfer fluids are applicable? Unused organic heat transfer fluids, including organic heat transfer fluids whose maximum service temperature at atmospheric pressure is higher than their boiling point (1.1)
Which type is not applicable? The applicability to silicone heat transfer fluids has not been evaluated (1.2)
What components make up the deterioration rate? High-boiling substances + low-boiling substances + gas-phase decomposition products + non-evaporable products (4.1, formula 5)
Test time requirement? Not less than 720 h for each sample (7.2)
Heating rate requirement? When the temperature rises to 50 °C below the test temperature, control it at 2 °C/min or below (7.2)
Temperature deviation requirement? At any point (including the heating wall) not exceeding ±1 °C of the test temperature (7.2)
Minimum volume of glass ampoule? At least 15 mL (6.1.2)
How many should be prepared for each sample? At least 3 (7.1)
When may gas-phase decomposition products be ignored? When the mass fraction is below 0.5% (7.5.1 note)
When may non-evaporable products be ignored? When the mass fraction is below 0.5% (7.5.2 note)
Up to which fraction is reported in simulated distillation? Only report the boiling range distribution results of fractions with a final boiling point before 538 °C (7.4.2)
Vacuum degree requirement for bulb tube distillation? At the end of distillation the pressure reaches below 10 Pa±0.2 Pa (7.4.3)
Heating temperature for bulb tube distillation? Slowly heat to 250 °C, with deviation not exceeding ±1 °C (7.4.3)
Limit for the volatile portion in the residue? Shall be less than 0.1% of the total mass of the organic heat transfer fluid (7.4.3)
How is the value reported for the deterioration rate? Take the average of 3 test results, accurate to one decimal place (8.7)
Which method standards are cited? HG/T 3115, SH/T 0558—1993
Gas chromatography column resolution requirement? Capillary chromatographic column of 3~8 (6.1.8, see SH/T 0558—1993 in 8.3)
Nitrogen purity requirement? Mass fraction above 99.99% (6.2.1)
Source of reference oil? Reference oil No. 1 or No. 2, boiling range distribution see SH/T 0558—1993 Appendix B (6.2.2)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.