GB/T 258-2025 Determination of acidity of light petroleum products

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

The acidic substances in light petroleum products are extracted with ethanol, and in the presence of a color indicator, titrated with potassium hydroxide ethanol standard titration solution. (See Chapter 4 Method summary)

4. Reagents and materials (purity / preparation)

Preparation and standardization (see Chapter 8 Test preparation):

5. Instruments and equipment

Annex A (normative) Fully automatic acidity tester for light petroleum products:

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis Procedure

8.1 Sample Preparation (9.1)

The diesel sample amount is 20 mL, and the sample amounts for other samples are all 50 mL. Measure the sample under 20 ℃±3 ℃.

8.2 Manual Titration (9.2)

9.2.1 95% Preparation of the ethanol-indicator solution mixture:

9.2.2 Determination of acidity:

8.3 Automatic Titration (9.3)

8.4 Titration Time (9.4)

During each titration process, the time elapsed from stopping heating the conical flask to reaching the titration endpoint shall not exceed 3 min.

8.5 Quality Control (Chapter 10)

Confirm the performance of the procedure and equipment by analyzing quality control (QC) samples. It is recommended to analyze QC samples at least monthly to ensure the reliability and accuracy of the results. Control chart techniques may be used to analyze QC samples. If the QC sample results show that the acidity test system is in a state of statistical out-of-control, the cause needs to be found and corresponding measures taken. Within the predetermined period of use, there should be a sufficient supply of QC samples, and the QC samples should be uniform and stable.

9. Qualitative and Quantitative and Calculation Formulas

9.1 Manual Titration Acidity Calculation (11.1)

The acidity X of the sample is calculated according to formula (1):

X = 56.1 × c × V / V1 × 100 ……………………(1)

Where:

9.2 Automatic Titration Acidity Calculation (11.2)

The acidity X of the sample is calculated according to formula (2):

X = 56.1 × c × (V2 − V0) / V1 × 100 ……………………(2)

Where:

9.3 Expression of Results (Chapter 12)

Take the arithmetic mean of the results of two parallel determinations as the acidity of the sample (calculated as KOH), and the result is accurate to 0.01 mg/100mL.

10. Precision

10.1 Manual Titration Precision (13.1)

Table 1 Manual Titration Precision Unit: mg/100mL

Acidity (calculated as KOH) Repeatability Reproducibility
<0.5 0.08 0.20
0.5~1.0 0.10 0.25
>1.0 0.20 —

10.2 Automatic Titration Precision (13.2)

r = 0.1479 X1^0.3829 ……………………(3)

Where: X1 —— the average value of two consecutive test results of the same sample.

R = 0.3197 X2^0.3829 ……………………(4)

Where: X2 — the average of two single, independent test results of the same test sample.

11. Report

Chapter 14 Test report: The report shall at least include the following contents:

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
Which products does this standard apply to? It applies to light petroleum products with obvious color change of the titration endpoint indicator, such as gasoline, naphtha, kerosene, jet fuel, diesel, etc. (Chapter 1)
What is the automatic instrument applicable to? It is only applicable to the determination of acidity of diesel products; the automatic titration acidity (calculated as KOH) determination range is 1.00 mg/100mL~12 mg/100mL. (Chapter 1)
What is the principle of the method? The acidic substances in light petroleum products are extracted with ethanol, and titrated with potassium hydroxide ethanol standard titration solution in the presence of a color indicator. (Chapter 4)
What is the diesel sample amount? 20 mL; all other samples are 50 mL, measured at 20 ℃±3 ℃. (9.1)
Which indicators are used for manual titration? Cresol red, alkali blue 6B, phenolphthalein. (5.4, 5.5, 5.6)
What is the concentration of potassium hydroxide ethanol standard titration solution? 0.05 mol/L. (8.1)
Titration time requirement? From stopping heating to reaching the titration endpoint, it shall not exceed 3 min. (9.4)
Manual titration acidity calculation formula? X = 56.1 × c × V / V1 × 100. (11.1 Formula (1))
Automatic titration acidity calculation formula? X = 56.1 × c × (V2 − V0) / V1 × 100. (11.2 Formula (2))
How are results expressed? Take the arithmetic mean of two parallel determination results, accurate to 0.01 mg/100mL. (Chapter 12)
Manual titration repeatability limit? Acidity <0.5: 0.08; 0.5~1.0: 0.10; >1.0: 0.20 (unit mg/100mL). (Table 1)
Manual titration reproducibility limit? Acidity <0.5: 0.20; 0.5~1.0: 0.25; >1.0: — (unit mg/100mL). (Table 1)
Automatic titration repeatability formula? r = 0.1479 X1^0.3829. (13.2.2 Formula (3))
Automatic titration reproducibility formula? R = 0.3197 X2^0.3829. (13.2.3 Formula (4))
Quality control sample requirements? It should be similar in composition to the test sample, and its average value and control limits should have been determined; it is recommended to analyze at least once a month. (5.7, Chapter 10)
What does the test report include? Sample name, number; standard used; method used; results; observed abnormal phenomena; test date. (Chapter 14)
What are the main components of the automatic instrument? Digital camera, image processing system, automatic control system, illumination light source (LED, color temperature 6500 K±100 K). (A.2)
Automatic instrument acidity measurement range? 0~20 mg/100mL (calculated as KOH). (Table A.1)
Automatic instrument titration volume graduation? 0.02 mL. (Table A.1)
Automatic instrument reflux time? 5 min. (Table A.1)
Automatic instrument determination time? <30 min. (Table A.1)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.