GB/T 25963-2022 Determination of aromatic hydrocarbon content in middle distillates containing fatty acid methyl esters — High performance liquid chromatography with differential refractive index detector

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

Warning (original): aromatic compounds are highly volatile and flammable, and their vapors can form explosive mixtures with air; inhalation or skin contact may cause acute or chronic harm; may cause water pollution.

Standard substance A B C D
o-Xylene 4.0 1.0 0.25 0.05
Fluorene 2.0 1.0 0.25 0.02
Phenanthrene 0.4 0.2 0.05 0.91

(Note: the phenanthrene D value in Table 1 is originally “0.91”, suspected to be source-text extraction noise, requires confirmation against the source standard (source-text extraction).)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and Quantitative Calculation Formulas

10. Precision

Compound type Measurement range (mass fraction)/% Repeatability (mass fraction)/% Reproducibility (mass fraction)/%
Monocyclic aromatics 6~30 0.032X_1 − 0.161 0.144X_2 − 0.344
Dicyclic aromatics 1~10 0.151X_1 − 0.036 0.363X_2 − 0.087
Tricyclic+ aromatics 0~2 0.092X_1 + 0.098 (the source source-text extraction does not provide it, requires confirmation (source-text extraction))
Polycyclic aromatics 1~12 0.074X_1 + 0.186 0.442X_2 + 0.471
Total aromatics 7~42 0.185X_1 + 0.465 (the original source-text extraction line order is suspected to be misplaced, requires confirmation against the source standard (source-text extraction)) 0.040X_2 − 0.070 (the original source-text extraction is written as "0.040X" 0.070", requires confirmation against the source standard (source-text extraction))

(Note: In Table 2, the values for tricyclic + aromatics reproducibility and total aromatics repeatability/reproducibility are doubtful due to source-text extraction line misalignment, requires confirmation against the source standard (source-text extraction).)

Compound type Measurement range (mass fraction)/% Repeatability (mass fraction)/% Reproducibility (mass fraction)/%
Total aromatics 0.2~2.0 0.039 1X_1 + 0.077 2 0.171 3X_2 + 0.346 9

11. Report

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
Which version does this standard replace? Replaces GB/T 25963—2010; this is the first revision.
Publication and implementation dates? Published on 2022-10-12, implemented on 2022-10-12.
Which samples is it applicable to? Diesel with FAME volume fraction not greater than 30%, high-wax diesel with FAME volume fraction not greater than 7%, and petroleum fractions with distillation range 150 °C~400 °C.
What are the two procedures? Procedure A (diesel and petroleum fractions, requires n-heptane dilution); Procedure B (high-wax diesel, direct injection).
Quantification range of Procedure A? Monocyclic aromatics 6%~30%, dicyclic aromatics 1%~10%, tricyclic + aromatics 0%~2%, polycyclic aromatics 1%~12%, total aromatics 7%~42% (mass fraction).
Quantification range of Procedure B? Total aromatics 0.2%~2% (mass fraction).
How are polycyclic aromatics and total aromatics obtained? Polycyclic aromatics = dicyclic aromatics + tricyclic + aromatics; total aromatics = monocyclic aromatics + dicyclic aromatics + tricyclic + aromatics.
What is the mobile phase? n-Heptane (HPLC grade).
Recommended flow rate? 0.8 mL/min–1.2 mL/min and keep constant (instrument capability range 0.5 mL/min–1.5 mL/min).
Injection volume? Usually 10 µL; may also be 3 µL~20 µL, provided that repeatability, sensitivity and linearity, and column resolution requirements are met.
Column temperature requirement? 20 °C~40 °C isothermal (±1 °C).
Column type? Amino-bonded (or polar amino/cyano-bonded) silica stationary phase, particle size 3 µm, 5 µm or 10 µm; Annex A recommends column length 150 mm–300 mm, inner diameter 4 mm–5 mm.
Detector? Differential refractive index detector, refractive index detection range 1.3~1.6.
How many system performance verification solutions are there? Two types: SCS1 and SCS2.
Elution order of SCS1? Cyclohexane, dodecylbenzene, o-xylene, hexamethylbenzene, naphthalene, dibenzothiophene, 9- methylanthracene.
Resolution requirement for cyclohexane and o-xylene? Between 5.7~10.
Working curve requirement? Straight line, correlation coefficient greater than 0.999, intercept less than ±0.01 g/100 mL.
Result expression precision? Expressed as mass fraction, accurate to 0.1%.
Precision confidence level? 95%.