GB/T 261-2008 Determination of flash point — Pensky-Martens closed cup method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and exclusions

3. Method principle

Pour the sample into the test cup, stir continuously at the specified rate, and heat the sample at a constant rate. At specified temperature intervals, with stirring interrupted, introduce an ignition source into the opening of the test cup so that the sample vapor flashes momentarily, and the lowest temperature at which the flash spreads over the liquid surface is the flash point at ambient atmospheric pressure; then use a formula to correct it to the flash point at standard atmospheric pressure. (Chapter 4)

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

Judge the reliability of test results (confidence level of 95%) according to the following provisions.

11. Report

14 The test report shall include at least the following:

  1. State the standard implemented and the test procedure used;
  2. Type and complete identification of the product tested;
  3. If possible, report the preheating temperature and preheating time (see 9.1.4);
  4. Ambient atmospheric pressure near the instrument (see 10.2.1 and 10.3.1);
  5. Test results (see Chapter 12);
  6. Note any differences from the specified test procedure by agreement or for other reasons;
  7. Date of test.

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
Which version does this standard replace? Replaces GB/T 261—1983; previous versions GB 261—1964, GB 261—1977, GB/T 261—1983.
Adoption of international standard? Modified adoption of ISO 2719:2002 (MOD).
Dates of publication and implementation? Published on 2008-08-25, implemented on 2009-02-01.
Which samples is it applicable to? Petroleum products, and chemical products such as varnishes and paints that do not form a surface film.
Which samples is it not applicable to? Water-containing paints or liquids containing highly volatile materials.
What does step A apply to? Paints and varnishes that do not form a surface film, unused lubricating oils, and other petroleum products not included in step B.
What does step B apply to? Residual fuel oils, diluted bitumen, used lubricating oils, liquids that tend to form a surface film, liquids with suspended particles, and highly viscous materials.
What is the basis for the arbitration test? The result of the manual test ignited with a flame ignition source (6.1.2).
Heating rate and stirring rate for step A? 5–6 °C/min; 90–120 r/min.
Heating rate and stirring rate for step B? 1.0~1.5 °C/min; 250 r/min±10 r/min.
Diameter of the ignition flame? 3mm~4 mm.
Flame descent and dwell time during ignition? Lower into the vapor space within 0.5s, dwell for 1 s, then quickly raise back to the original position.
Ignition interval when the expected flash point is ≤110°C? Ignite once for every increase of 1°C, starting from 23°C±5°C below the expected flash point.
Ignition interval when the expected flash point is >110°C? Ignite once for every increase of 2°C, starting from 23°C±5°C below the expected flash point.
Requirement for a valid result regarding the difference between the observed flash point and the initial ignition temperature? It should be within the range of 18°C~28°C; otherwise the result is invalid.
Barometric pressure correction formula? Tc = To + 0.25 (101.3 − p), limited to 98.0~104.7 kPa.
To what precision is the result reported? Corrected to 101.3 kPa, accurate to 0.5°C.
Instrument calibration frequency and criteria? Use CRM according to step A to calibrate at least once a year; the difference between the result and the value given by CRM is ≤R/√2.
For which sample type is the precision not applicable? The reproducibility is not applicable to 20 aviation lubricating oil.
What should the test report at least include? Standard and procedure, product type identification, preheating temperature/time (if possible), ambient atmospheric pressure, test results, explanation of differences, test date.
Which standards are referenced for sampling? GB/T 4756, SY/T 5317, or GB/T 3186.
Reference for the preparation of paint and varnish samples? GB/T 20777.
How many temperature ranges does the thermometer have? Three temperature ranges: low, medium, and high, selected according to the expected flash point.
Barometer accuracy requirement? 0.1kPa, a barometer that has been pre-calibrated to sea level readings must not be used.
Temperature control requirements for the heating bath/oven? Controlled within ±5°C, an explosion-proof oven is recommended.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.