Origin Standard

GB/T 34102-2017 Determination of 2,6- di-tert-butyl-p-cresol content in jet fuel — Differential pulse voltammetry

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key Answer Points
Standard number and year? GB/T 34102—2017
Method name? Determination of 2,6- di-tert-butyl-p-cresol content in jet fuel—Differential pulse voltammetry
Issue/implementation dates? Issued on 2017-07-31, implemented on 2018-02-01
Applicable object? Determination of 2,6- di-tert-butyl-p-cresol content in jet fuel
Measurement range? 8 mg/L~31 mg/L
Method principle? Differential pulse voltammetry, 2,6- di-tert-butyl-p-cresol is oxidized on a composite electrode, measure the peak current (unclear in the source text, requires confirmation against the source standard (source-text extraction))
Sampling basis? GB/T 4756
Precision basis? GB/T 6683
Standard curve correlation coefficient requirement? R (95% confidence level) ≥ 0.95
Standard solution concentration? 500 mg/L
Standard series concentration points? 0.0, 5.0, 15.0, 25.0 mg/L
Initial/final potential? −0.5 V / +0.5 V
Potential increment? 0.002 V
Pulse amplitude? 0.05 V
Pulse width? 0.06 s
Pulse interval? 0.02 s
Current range? 1×10⁻⁵ A/V
Electrode pretreatment time? 15 min~30 min
Number of replicate measurements? Each sample is repeated 5 times
Result unit and precision? mg/L, accurate to 0.1 mg/L
Repeatability r? 0.58x, 0.5 mg/L (as in the original text, requires confirmation against the source standard (source-text extraction))
Reproducibility R? 1.08x, 0.5 mg/L (as in the original text, requires confirmation against the source standard (source-text extraction)); when 18~24 mg/L, R = 3.2 mg/L
Calculation formula? c₀ = (b/k) × (V/V₀), V=10 mL, V₀=9 mL
Content of Appendix A? Standard curve regression calculation formulas (A.1)~(A.7)
Inapplicable objects? unclear in the source text, requires confirmation against the source standard (source-text extraction)
Reagent names and purity? Multiple places source-text extraction unclear in the source text, requires confirmation against the source standard (source-text extraction)
Specific electrode parameters? Partially unclear in the source text, requires confirmation against the source standard (source-text extraction)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.