GB/T 3535-2006 Determination of pour point of petroleum products

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After the test specimen is preheated, it is cooled at a specified rate, and the fluidity of the test specimen is checked every 3 ℃. The lowest temperature at which the test specimen is observed to be capable of flowing is recorded as the pour point.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

See Section 6 (6.1~6.11).

9. Qualitative and quantitative determination and calculation formulas

10. Precision

Judge the reliability of the test results according to the following provisions (confidence level of 95%).

11. Report

The test report shall include at least the following:

  1. complete information on the product tested;
  2. a statement that this standard is referenced;
  3. the test results;
  4. any differences from the test procedure of this standard as agreed or otherwise specified shall be noted;
  5. the test date;
  6. a statement of whether an automatic instrument was used for the determination test.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference for questions and answers

Question Key points of answer
Standard number and name GB/T 3535—2006 Determination of pour point of petroleum products
Which standard it replaces Replaces GB/T 3535—1983 "Determination of pour point of petroleum"
International standard adopted Modified adoption of ISO 3016:1994 (MOD)
Method principle After preheating, cool at the specified rate, check flowability every 3 ℃, and record the lowest temperature at which it can flow
Definition of pour point The lowest temperature at which an oil can flow when cooled under specified conditions
Scope of application Pour point of petroleum products; also describes the lower pour point procedure for fuel oils, heavy lubricating base oils and products containing residual fuel components
Whether crude oil is applicable The general procedure can be used for crude oil, but the precision does not apply; a dedicated method is under study
Test tube specifications Inner diameter 30.0–32.4 mm, outer diameter 33.2–34.8 mm, height 115~125 mm, wall thickness ≤1.6 mm, etched line distance from inner bottom 54 mm±3 mm
Jacket material Metal (glass jacket cancelled)
Cold bath bath temperature tolerance Specified temperature ±1.5 ℃
Timer requirement Measurement 30 s error not exceeding 0.2 s
Sample pretreatment above -33 ℃ 6.4: bath temperature above the expected pour point by 12 ℃ and at least 48 ℃, heat to 45 ℃ or above the expected pour point by 9 ℃ (whichever is higher), transfer to 24 ℃±1.5 ℃ bath
Sample pretreatment at -33 ℃ and below 6.5: heat in 48 ℃ bath to 45 ℃, cool in 6 ℃±1.5 ℃ bath to 15 ℃, change to a low-temperature thermometer, place in 0 ℃ bath
Transfer bath temperature nodes 9 ℃→-18 ℃; -6 ℃→-33 ℃; -24 ℃→-51 ℃; -42 ℃→-69 ℃
Calculation of results Add 3 ℃ to the recorded temperature, and take the average of two results from duplicate determinations
Repeatability Same operator, same instrument, same sample: the difference between two consecutive results shall not be greater than 3 ℃
Reproducibility Different operators, different instruments, same sample: the difference between two results shall not be greater than 6 ℃
Specification value not a multiple of 3 ℃ Test according to 6.9, and report pass or fail of the specification value
Lower pour point determination 6.10: heat to 105 ℃ with stirring, then pour into the test tube, and determine according to 6.2~6.8
Automatic instrument May be used, but precision has not been established; in case of dispute, the manual method is the referee
Report contents Product information, reference to this standard, test results, differences, test date, whether an automatic instrument was used
Thermometer specifications Annex A (normative annex), Table A.1 gives the specifications of 3 partial-immersion liquid-in-glass thermometers

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.