Origin Standard

GB/T 511-2010 Determination of mechanical impurities in petroleum and petroleum products and additives

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Weigh a certain amount of sample, dissolve it in the solvent used, filter with a filter paper or sintered-glass filter of constant weight, and the impurities retained on the filter paper or sintered-glass filter are the mechanical impurities. (Chapter 3 Method summary)

4. Reagents and materials (purity / preparation)

4.1 Reagents

4.2 Materials

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

Sample Sample mass/g Weighed to the nearest/g Ratio of solvent volume to sample mass
Petroleum products: 100 ℃ kinematic viscosity ≤20 mm²/s not provided in the available source not provided in the available source not provided in the available source
Petroleum products: 100 ℃ kinematic viscosity >20 mm²/s not provided in the available source not provided in the available source not provided in the available source
Petroleum: mechanical impurities not more than 1% (mass fraction) 50 0.01 5~10
Boiler fuel: mechanical impurities not more than 1% (mass fraction) 25 0.01 5~10
Boiler fuel: mechanical impurities more than 1% (mass fraction) 10 0.01 ≤15
Additives 10 0.01 ≤15

Note: In Table 1, the sample mass, weighing precision, and dilution ratio for the two rows of "petroleum products" are incomplete in the source source-text extraction (numbers such as 0.05, 0.03, 2–4, 4–6 appear but their correspondence is unclear), requires confirmation against the source standard (source-text extraction).

8. Analysis procedure

9. Qualitative and Quantitative Determination and Calculation Formula

The mechanical impurity content of the sample w% (mass fraction) is calculated according to formula (1):

w = [(m2 − m1) − (m4 − m3)] / m5 × 100 … (1)

Where:

Note: The original source-text extraction formula layout is incomplete (rendered as “w= (m2[unreadable separator]m) (ms-ma2 × 100”); the above formula has been organized according to 7.9 blank test correction and the symbol explanations in the formula, requires confirmation against the source standard (source-text extraction).

10. Precision

Judge the reliability of the determination results according to the following provisions (95% confidence level).

Table 2 Repeatability and Reproducibility

Mechanical impurities (mass fraction)/% Repeatability (mass fraction)/% Reproducibility (mass fraction)/%
≤0.01 0.002 5 0.005
>0.01~0.1 0.005 0.01
>0.1~1.0 0.01 0.02
>1.0 0.10 0.20

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key points of answer
What does this standard determine? Mechanical impurities in petroleum, liquid petroleum products, and additives (Chapter 1)
What is it not applicable to? Lubricating grease and asphalt (Chapter 1)
Method principle? The sample is dissolved in solvent, filtered through constant-weight filter paper or a fritted glass filter, and the residue is the mechanical impurities (Chapter 3)
For arbitration, use filter paper or a fritted glass filter? The result obtained by filter paper filtration shall prevail (7.4 Note 2)
Filter paper specification? Medium speed, diameter 11 cm quantitative filter paper, conforming to GB/T 1914 (5.2.1)
Fritted glass filter specification? Funnel type, P10 (pore size 4 μm~10 μm), diameter 40 mm, 60 mm, 90 mm (4.13)
Oven temperature? 105 ℃±2 ℃ (4.11, 6.3, 7.7)
First drying time? Not less than 45 min (6.3, 7.7)
Second drying time? 30 min (6.3, 7.7)
Weighing accuracy? Weigh to the nearest 0.000 2 g (6.3, 7.7)
Constant weight criterion? The difference between two consecutive weighings does not exceed 0.000 4 g (6.3, 7.7)
Solvent oil preheating temperature? 40 ℃ (7.1.2)
Toluene preheating temperature? 80 ℃ (7.1.2)
What solvent is used for determining petroleum, dark petroleum products, additive-containing lubricating oils, and additives? Toluene (7.1.1)
Ethanol-toluene mixed solvent ratio? 95% ethanol:toluene = 1:4 (volume ratio) (5.1.4)
Ethanol-ether mixed solvent ratio? 95% ethanol:ether = 4:1 (volume ratio) (5.1.5)
What is used for chloride ion testing? 0.1 mol/L silver nitrate aqueous solution; if the filtrate is not turbid, there are no chloride ions (5.1.6, 7.6)
Blank test requirement? During the test, a blank test correction for the solvent should be carried out simultaneously (7.9)
Result value? Take the arithmetic mean of two repeat determination results (9.1)
Determination limit for no mechanical impurities? When the content is at or below 0.005% (mass fraction) (including 0.005%), it may be considered that there are no mechanical impurities (9.2)
Repeatability (≤0.01%)? 0.002 5% (mass fraction) (Table 2)
Reproducibility (≤0.01%)? 0.005% (mass fraction) (Table 2)
Repeatability (>1.0%)? 0.10% (mass fraction) (Table 2)
Reproducibility (>1.0%)? 0.20% (mass fraction) (Table 2)
What are the referenced documents? GB/T 1914, GB/T 6682, SH 0004 (Chapter 2)
International/foreign standard adopted? Modified adoption of ГОСТ 6370—1983 (1997) (Foreword)
Which standard does it replace? Replaces GB/T 511—1988 (Foreword)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.