Origin Standard

GB/T 512-1965 Determination of Water in Lubricating Grease

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

A certain amount of sample is mixed with an anhydrous solvent, and its water content is determined by distillation and expressed as a weight percentage.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

The difference between two repeated determination results shall not exceed one graduation above the portion occupied by water in the receiver.

11. Report

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A reference

Question Key answer points
What does this standard measure? The water content of lubricating grease; the result is expressed as a weight percentage.
What is the method principle? The sample is mixed with an anhydrous solvent, and the water content is determined by distillation.
How much sample is weighed? 20–25 grams, weighed to the nearest 0.1 grams; when the expected water content is above 10%, reduce to 10–15 grams.
What solvent is used? Straight-run gasoline with an initial boiling point not lower than 90 °C and a dry point not higher than 150 °C, dried with anhydrous calcium chloride and filtered.
How much solvent is added? 150 milliliters.
What is the reflux rate requirement? 2~4 drops per second.
What is the distillation time limit? Shall not exceed 1 hours.
When is distillation stopped? When the volume of water in the receiver no longer increases and the upper solvent layer has completely become transparent.
How is turbid solvent handled? Place the receiver in hot water for 20~30 minutes to clarify it and then cool it again.
What should be done if agglomeration, bumping, or emulsification and foaming occur? It is permissible to add 5~10 grams of oleic acid or stearic acid, and according to SY 2707 determine the free alkali to convert the correction value (total alkali amount × 0.45), subtract it from the water reading; if the corrected value is negative, the water content is considered "none".
Calculation formula? X = V × 100 / G, where V is the volume of water in the receiver (milliliters), and G is the sample weight (grams).
How is the result reported? Take the arithmetic mean of two repeated determination results; when the water is less than 0.03 milliliters, it is considered a trace.
Precision requirement? The difference between two repeated determination results shall not exceed one graduation above the portion occupied by water in the receiver.
Arbitration test conditions? The difference between the cooling water temperature and room temperature shall be controlled within 5 °C.
Which documents are referenced? GB 260, SY 2707, SYB 2704-59 (void).
What standard did it replace? The former Ministry of Petroleum Industry standard SYB 2704-59 "Determination of Water in Lubricating Grease" is void.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.