Origin Standard

GB/T 8018-2015 Determination of oxidation stability of gasoline Induction period method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and Quantitative Determination and Calculation Formulas

10. Precision

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key points of answer
Which old standard does this standard replace? Replaces GB/T 8018-1987 "Determination of oxidation stability of gasoline (induction period method)".
Which foreign standard is adopted? Adopted by redrafting method with modifications to ASTM D525-12a.
What is the scope of application? Applicable to products such as motor gasoline, blending component oils for motor ethanol gasoline, and motor ethanol gasoline.
What is the turning point? A point on the pressure-time curve, before which the pressure drop of 15 min reaches 14 kPa, and after which the pressure drop of 15 min is not less than 14 kPa.
What is the induction period? The time elapsed from placing the oxygen bomb into the 100 ℃ bath to the turning point, expressed in min.
Temperature and pressure conditions before oxygen filling? Fill oxygen to 690 kPa~705 kPa at 15 ℃~25 ℃.
What is the oxidation bath temperature? 98 ℃~102 ℃.
What is the sample amount? 50 mL±1 mL.
Pressure reading interval? Continuous recording; when using an indicating pressure gauge, record once every 15 min or shorter.
Conditions for invalidating the test? If leakage increases within 30 min from the start of the test (stable pressure drop within 15 min exceeds 14 kPa), the test is invalidated.
Cooling and pressure release requirements? Cool in air or ≤35 ℃ water to near room temperature within 30 min; pressure release rate shall not exceed 345 kPa/min.
How is the induction period of 100 ℃ calculated? When the test temperature is higher than 100 ℃ use formula (1), when lower than 100 ℃ use formula (2), constant 0.101.
How is the report expressed? The calculated result is rounded to an integer and reported as the induction period of the sample at 100 ℃.
How to report if the turning point does not appear? If there are product specification requirements, the test may be stopped and reported as the induction period greater than the product specification value; for slow oxidation, report as a slowly oxidizing fuel and report the total test time and total pressure drop.
What is the repeatability r? Same operator, same laboratory, same instrument, the difference between two consecutive results shall not exceed 5% of the arithmetic mean.
What is the reproducibility R? Different operators, different laboratories, different instruments, the difference between two independent results shall not exceed 10% of the arithmetic mean.
Is the bias determined? The bias has not been determined in this standard.
What are the requirements for sampling manganese-containing gasoline? Protect from light during sampling.
Toluene purity requirement? Analytical reagent grade, or purity ≥99%.
Acetone purity requirement? Chemical reagent grade.
Oxygen purity requirement? Pure oxygen, or purity ≥99.6%.
Pressure relief valve actuation pressure? Relieves pressure when pressure is greater than 1530 kPa (±10%).
Oxygen bomb wall thickness requirement? At least 5 mm.
Oxygen bomb material requirements? Capable of withstanding 1240 kPa working pressure at 100 ℃, with ultimate strength at least equal to that of 18% Cr and 8% Ni alloy oxygen bombs; Y12Cr18Ni9 (S30317) or 06Cr19Ni10 (S30408) may be used.
Liquid bath capacity requirement? Not less than 18 L for one oxygen bomb, and increase by 8 L for each additional oxygen bomb; bath liquid depth not less than 290 mm.
Immersion depth of the top of the oxygen bomb cover? At least immersed 50 mm below the bath liquid surface.
Is oxygen filling required for solid bath temperature calibration? No oxygen filling is required, and oxygen filling operation is unreasonable.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.