Origin Standard

GB/T 8928-2008 Standard Test Method for Density of Solid and Semi-Solid Petroleum Asphalt

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Applicable scope and non-applicability

3. Method principle

Using a pycnometer, at the specified temperature, separately determine the mass of the same volume of petroleum asphalt and water, and calculate the relative density and density of the petroleum asphalt according to the formula (Chapter 4).

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

8.1 Apparatus preparation (Chapter 8)

8.2 Pycnometer calibration (Chapter 9)

8.3 Determination of relative density of semi-solid petroleum asphalt (10.1)

8.4 Determination of relative density of solid petroleum asphalt (10.2)

9. Qualitative and Quantitative Determination and Calculation Formulas

10. Precision

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key points of answer
What is the name of this standard method? Determination of density of solid and semi-solid petroleum asphalt by the pycnometer method.
Which samples are applicable? Solid and semi-solid petroleum asphalt.
What is it not applicable to? Solid petroleum asphalt with relative density less than 1.000.
What is the test temperature? 25 ℃±0.1 ℃.
Which standard is followed for sampling? GB/T 11147.
What is the balance sensitivity requirement? 0.0005 g.
What is the volume range of the pycnometer? 24 mL~30 mL, with mass not exceeding 40 g.
What is the upper heating limit for semi-solid test samples? It must not exceed its estimated softening point 110 ℃, and the time must not exceed 60 min.
What are the oven conditions for semi-solid test samples? Above the estimated softening point by 100 ℃–110 ℃, maintained for 20 min–30 min.
What particle size is sieved for solid test samples? 0.6 mm~2.5 mm.
What amount of solid test sample is used? Not less than 5 g.
What are the residual pressure and time for vacuum degassing? 2.7 kPa~3.3 kPa for at least 15 min; repeat if necessary and evacuate again for 15 min.
What is the symbol for relative density? D.
What is the symbol for density? ρ (the original source-text extraction is p; requires confirmation against the source standard).
What value is taken for the density of water at 25 ℃? 0.9971 g/cm³.
What is the precision of relative density for semi-solid? Repeatability 0.002, reproducibility 0.005.
What is the precision of relative density for solid? Repeatability 0.007, reproducibility 0.011.
What is the precision of density for semi-solid? Repeatability 0.002 g/cm³, reproducibility 0.005 g/cm³.
What is the precision of density for solid? Repeatability 0.007 g/cm³, reproducibility 0.011 g/cm³.
What is the reporting precision for relative density? Arithmetic mean of two parallel determinations, accurate to the 3th decimal place.
What is the reporting precision for density? Accurate to 0.001 g/cm³.
What should be done if repeatability is exceeded? The test is invalid and shall be retested.