Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key points of answer
Which old standard does this standard replace? Replaces SH/T 0230—1992 "Determination of liquefied petroleum gas composition (chromatographic method)"
What are the publication and implementation dates of this standard? Published on 2019-06-04, implemented on 2019-10-01
What does this standard apply to? Determination of hydrocarbon composition in finished liquefied petroleum gas; it may also be used for the determination of hydrocarbon and oxygenate components in liquefied petroleum gas containing oxygenates (dimethyl ether, methyl tert-butyl ether, acetone, methanol, etc.)
What are the determination ranges for each component? Hydrocarbons 0.01%~100%; dimethyl ether 1%~40%; methyl tert-butyl ether 0.01%~1%; methanol 0.01%~1%; acetone 0.01%~1% (all are volume fractions)
How many chromatographic analysis systems are there? Two: System 1 (single column, single valve, single detector, pure hydrocarbon liquefied petroleum gas); System 2 (dual column, dual valve, dual detector, liquefied petroleum gas containing oxygenates)
What are the chromatographic column configurations of System 1 and System 2? System 1: Al₂O₃ column (30 m×0.53 mm×15 μm); System 2: chromatographic column 1 is the same as System 1, chromatographic column 2 is a Lowox column (10 m×0.53 mm×10 μm), plus a guard column and a connecting column
What is the recommended detector? Hydrogen flame ionization detector with electronic flow controller (FID)
What are the carrier gas, fuel gas, combustion-supporting gas, and makeup gas respectively? Carrier gas: helium (≥99.999%); fuel gas: hydrogen (≥99.999%); combustion-supporting gas: compressed air; makeup gas: nitrogen (≥99.999%)
What is the typical column temperature program? Initial temperature 90 ℃ hold for 1 min, then raise to 180 ℃ at 6 ℃/min and hold for 30 min
What are the injection methods? Liquid valve injection or flash evaporator injection
What is the pressure requirement for liquid valve injection? Withstand at least 1380 kPa
What is the working temperature requirement for the flash evaporator? At least withstand 1380 kPa at 100 ℃
What is the precision requirement for liquid valve injection? The relative standard deviation of the peak area of each component is less than 3%
What is the precision requirement for flash evaporator injection? The relative standard deviation of the peak area of each component is less than 4%
What standard is the preparation of calibration samples based on? GB/T 5274/ISO 6142
What method is used for the quantification of hydrocarbons? Calibrated normalization method (system 1)
What method is used for the quantification of oxygenates? Calibration curve method (equation 2), with a correlation coefficient not less than 0.990
What method is used for the quantification of hydrocarbons in system 2? Difference calibrated normalization method (equation 4)
To what precision are the results reported? 0.01%
From how many laboratories do the precision data come? Test results of 9 laboratories on 10 mixed liquefied petroleum gas samples
Is the bias determined? Not determined, because there is no suitable reference material
How is a new chromatographic column aged? Chromatographic column 1: 180 ℃ aging 8 h; chromatographic column 2: raise from 2 ℃/min to 300 ℃ and hold for 10 h
How is the dimethyl ether cut time determined? Prepare a sample A containing dimethyl ether and toluene, and take the toluene peak time minus 0.5 min as the valve 2 opening time
What standard is sampling based on? SH/T 0233
What is Appendix A? An informative appendix, providing a reference chromatogram for the qualitative analysis of unknown oxygenates in complex liquefied petroleum gas samples (OXY-LPG standard sample distribution on the Lowox column)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.