Origin Standard

NB/SH/T 0430-2019 Determination of equilibrium reflux boiling point of brake fluid

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis procedure

9. Qualitative and quantitative determination and calculation formulas

Temperature range Correction value for 1Pa atmospheric pressure difference ×10⁻⁴ Correction value for 1mmHg atmospheric pressure difference ×10⁻⁴
<100°C 2.25 3.00
100°~190°C 2.92 3.90
>190°C 3.00 4.00

10. Precision

Equilibrium reflux boiling point, °C Repeatability, °C Reproducibility, °C
<205 ≤1.5 ≤4.0
205~232 ≤2.0 ≤5.0
>232 ≤4.0 ≤10.0

11. Report

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference for questions and answers

Question Key points of answer
Which version does this standard replace? Replaces SH/T 0430—1992 "Determination of equilibrium reflux boiling point of brake fluid".
What is the scope of application? Applicable to the determination of the equilibrium reflux boiling point of motor vehicle brake fluid; specifies the determination methods for equilibrium reflux boiling point and wet equilibrium reflux boiling point.
Sample amount for equilibrium reflux boiling point? 60mL test sample, add to 100mL flask, place 3 to 4 boiling stones.
What are the two methods for wet equilibrium reflux boiling point? A method (humidification method) and B method (water addition method).
How is the humidification endpoint of the A method judged? The water content of the humidity control liquid reaches 3.70%±0.05% (average of duplicate samples).
Water addition amount for the B method? Inject 2.1mL distilled water into the 60mL test sample.
Thermometer requirements? Meets the requirements of GB-28 in GB/T 514.
Reflux rate requirements? Initially 1 drops/s to 5 drops/s; thereafter adjust within 10min to 1 drops/s to 2 drops/s, maintain for 2min.
Reading requirements? Read once every 30s, four consecutive times, accurate to 0.2°C.
Calculation formula? TERBP = T observed + Δt correction + Cc.
Precision of equilibrium reflux boiling point? See Table 2: <205°C repeatability ≤1.5, reproducibility ≤4.0; 205 to 232°C repeatability ≤2.0, reproducibility ≤5.0; >232°C repeatability ≤4.0, reproducibility ≤10.0.
Precision of wet equilibrium reflux boiling point A method? Repeatability and reproducibility have not yet been established.
Reporting accuracy? Accurate to 0.2°C.
Sample amount requirement? Not less than 1000mL.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status