Origin Standard

NB/SH/T 0505-2017 Determination of shear stability of polymer-containing oils — Ultrasonic shear method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and test sample preparation

8. Analytical procedure

8.1 Operating procedure of the ultrasonic shear test apparatus (7.1)

8.2 Calibration procedure using reference oil (7.2)

8.3 Formal test (7.3)

8.4 Instrument preparation (Chapter 6)

9. Qualitative and quantitative determination and calculation formulas

10. Precision

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key Answer Points
What is the standard method number and name? NB/SH/T 0505—2017 Determination of shear stability of polymer-containing oils—Ultrasonic shear method
Which version does it replace? Replaces SH/T 0505—1992
Publication and implementation dates? Published on 2017-12-27, implemented on 2018-06-01
Which oils is it applicable to? Polymer-containing hydraulic oils and internal combustion engine oils
What is the method principle? The energy concentrator contact rod performs ultrasonic shearing on the test sample, the viscosity change is measured according to GB/T 265, and the viscosity decrease rate is calculated
Standard shear test conditions? Test sample 30 mL, water bath temperature 38 ℃, shearing time 10 min
Temperature for viscosity measurement after shearing? 40 ℃
What is the reference oil? RIPP-JQ- reference 2 oil (the original text elsewhere writes RIPP-J9- reference 2 oil, requires confirmation against the source standard (source-text extraction))
Requirement for reference oil viscosity decrease rate? 16%±0.6%
Specifications of the energy concentrator output end? Diameter 20 mm cylindrical rod, end face without center hole, without chamfer, Ra not greater than 1.6 μm
Resonance frequency? 20 kHz±1 kHz
How much test sample is taken? 30 mL, injected into 100 mL glass beaker
How many times is the formal test measured? 2 times, each time 10 min
How are results reported? Take the arithmetic mean of two replicate determination results, retained to two decimal places
Repeatability formula? r = 0.38X^0.095 (exponent requires confirmation against the source standard (source-text extraction))
Reproducibility formula? R = 1.15X^0.095 (exponent requires confirmation against the source standard (source-text extraction))
Precision test scale? 5 samples, 11 laboratories interlaboratory test, calculated according to GB/T 6683
Is there bias? No bias
Calibration frequency? Before each startup test 1 times~2 times; for continuous operation over 24 h, calibrate once every 24 h
What are the normative references? GB/T 265, GB 1922—2006, GB/T 6682—2008, GB/T 6683, GB/T 15894—2008