Origin Standard

NB/SH/T 0570-2017 Determination of platinum content in reforming catalysts - Spectrophotometric method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After the sample is subjected to high-temperature treatment at 550°C, it is dissolved with hydrochloric acid, phosphoric acid, and hydrogen peroxide. The tetravalent platinum in the solution reacts with the reducing agent stannous chloride under a certain hydrochloric acid acidity to form a yellow chloroplatinic acid tin complex (the extracted name of the complex is garbled; requires confirmation against the source standard (source-text extraction)). The absorbance of the color-developing solution of this complex is measured with a spectrophotometer, and the platinum content in the sample is calculated by converting the absorbance through the average conversion factor.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

Table 1 Sample weighing specification

Platinum mass fraction/% Sample weight/g
0.200~0.400 0.50~0.25 (accurate to 0.1mg)
0.400~0.700 0.25~0.15 (accurate to 0.1mg)

Note: When the sample solution is also to be used for determination of other elements (such as rhenium) besides platinum content, the sample weight may be increased [for example, when the platinum mass fraction is 0.400%, weigh about 1g sample (accurate to 0.1mg)], dissolve the sample according to the dissolution method in 8.1.1, and transfer to a 100mL volumetric flask, dilute with water to the mark, and shake well. Pipette a portion of the solution into a 100mL volumetric flask so that the platinum content still complies with clause 7.4 within the range of 0.5mg~1.5mg, and dilute with water to not exceed 60mL. The remaining solution is for determination of other elements.

8. Analytical procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

Judge the reliability of test results according to the following provisions (95% confidence level):

11. Report

Take the arithmetic mean of two repeated determination results as the determination result, and retain three decimal places.

12. Reference Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key Answer Points
What does this standard measure? Platinum content in reforming catalysts, spectrophotometric method
Applicable platinum mass fraction range? 0.200%~0.700%
Which catalysts are applicable? Fresh and used monoplatinum, platinum-tin, and platinum-rhenium reforming catalysts with alumina as support; also applicable to other activated alumina-supported platinum-containing catalysts when no interference is confirmed
Which elements interfere? Palladium, ruthenium, rhodium significantly interfere
Rhenium content limit for platinum-rhenium catalysts? Rhenium content in the colored solution not greater than 15wg/mL (requires confirmation against the source standard (source-text extraction))
High-temperature treatment conditions? 550°C±25°C, furnace door slightly open, above 2h, shake 1~2 times
Grinding particle size? Less than 0.104mm
Measurement wavelength? 403nm (monoplatinum, platinum-tin); 460nm (platinum-rhenium)
Cuvette specification? 1cm
Color development standing time? 1h
Platinum content control range? 0.5mg~1.5mg
Ignition basis determination conditions? 1000°C±25°C, constant temperature 3h, vacuum desiccator cooling 1h
Repeatability limit? Not greater than 0.005%
Reproducibility limit? Not greater than 0.013%
Report decimal places? Three decimal places
Which standard does it replace? SH/T 0570—1993
Which standard is modified and adopted? ASTM D4642-04 (2016)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.