Origin Standard

NB/SH/T 0606-2019 Determination of hydrocarbon types in middle distillates — Mass spectrometry

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

According to Annex A, the saturated hydrocarbon and aromatic hydrocarbon fractions obtained by separating a middle distillate (including biodiesel blended fuel) sample are respectively subjected to mass spectrometric determination. The concentrations of various hydrocarbon types are determined by summing characteristic mass fragments. The average carbon number of hydrocarbons is estimated from the mass spectral data, and calculation is performed based on correction data determined from the average carbon numbers of various hydrocarbon types. The results for each fraction are normalized according to the mass fractions obtained by separation, and the results are expressed as mass fractions.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis steps

9. Qualitative and quantitative and calculation formulas

10. Precision

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key Answer Points
What distillation range does this standard apply to? 170 ℃ to 365 ℃ (recovery temperature for volume fraction 5% to 95% determined using GB/T 6536)
Does it apply to biodiesel blend fuels? Applies to biodiesel blend fuels containing fatty acid methyl esters with volume fraction not greater than 20%
How many hydrocarbon classes can be determined? Eleven classes: paraffins, monocyclic naphthenes, dicyclic naphthenes, tricyclic naphthenes, alkylbenzenes, indans and/or tetralins, CₙH₂ₙ₋₁₀, naphthalenes, CₙH₂ₙ₋₁₄, CₙH₂ₙ₋₁₆, tricyclic aromatic hydrocarbons
What is the method principle? Separate saturated hydrocarbon and aromatic hydrocarbon fractions according to Appendix A, perform mass spectrometric determination separately, determine the concentration of each hydrocarbon class based on the sum of characteristic mass fragments, calculate using calibration data determined by average carbon number, and express results as mass fraction
What is the effect of high sulfur content? If the sulfur content mass fraction is greater than 0.25%, it will interfere with the spectral peaks used for hydrocarbon calculations
What is the effect of high olefin content? If the olefin content mass fraction is greater than 5.0%, it will affect the determination results of various saturated hydrocarbons
What are the mass spectrometer calibration conditions? Adjust the repeller so that the n-hexadecane molecular ion peak m/e 226 is maximum; perform mass scanning from m/e 40 to 292; ionization voltage 70 eV, ionization current 10 μA to 70 μA (requires confirmation against the source standard (source-text extraction))
Recommended gas chromatography column conditions? Quartz capillary column, 30 m × 0.25 mm × 0.25 μm, non-polar stationary phase
Gas chromatography oven program? 60 ℃ hold for 2 min, ramp at 40 ℃/min to 300 ℃, hold for 5 min
What is the internal standard? n-Triacontane dissolved in n-hexane, concentration 0.001 g/mL to 0.005 g/mL
Fatty acid methyl ester density value? At 20 ℃, dₚ = 880.0 kg/m³
Sample density determination method? SH/T 0604
Precision collaborative test scale? 7 laboratories, 28 samples (10 middle distillates + 18 biodiesel blend fuels)
Can bias be determined? No, because there is no reference material for determining bias
Result reporting precision? Mass fraction accurate to 0.1%
Difference between method 1 and method 2? Method 1 applies to hydrocarbon-based middle distillates containing no fatty acid methyl esters; method 2 applies to biodiesel blend fuels containing fatty acid methyl esters with volume fraction not greater than 20%
Solid phase extraction column specifications? Solid phase extraction column containing 1.5 g stationary phase, 3 mL
Can the solid phase extraction column be reused? Cannot be reused
Silica gel activation conditions for chromatography? Constant temperature activation at 150 ℃ for 5 h
Yield requirement for chromatography? Should reach 95% or above