Origin Standard

NB/SH/T 0811-2010 Determination of oxidation stability of unused hydrocarbon insulating oils

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and exclusions

3. Method principle

A solid copper catalyst is placed in the sample to be tested, air is passed in at a constant rate, and after maintaining at a temperature of 120 ℃ for a certain time, the antioxidant capacity is evaluated by measuring the volatile acid value, oil-soluble acid value, and sediment content of the oxidized oil.

4. Reagents and materials (purity / preparation)

4.1 Reagents

4.2 Materials

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

11. Report

Not provided in the available source (the content of Chapter 11 of the main text is source-text extraction missing; requires confirmation against the source standard (source-text extraction)).

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference for questions and answers

Question Key points of answer
Standard number and name? NB/SH/T 0811—2010 Determination method for oxidation stability of unused hydrocarbon insulating oils
International standard adopted? Modified adoption of IEC 61125—1992 (MOD), including IEC 61125 AMD1—2004 amendment 1
Which method is adopted? Only method C in IEC 61125—1992 is adopted; methods A and B are not included
Scope of application? Unused mineral insulating oils, with or without added inhibitor
Method principle? Solid copper catalyst, constant-rate air flow, after oxidation at 120 ℃ measure volatile acid value, oil-soluble acid value and sediment
Test sample mass? 25 g±0.1 g
Oxidation gas and flow rate? Air; 0.15 L/h±0.015 L/h
Test temperature? 120 ℃±0.5 ℃
Test time? 164 h; for improved oils, multiples of 168 h may be used; for inhibited commercial oils, 500 h is suitable for most
Termination condition for induction period determination? Volatile acid value clearly exceeds 0.1 mgKOH/g
Catalyst? Soft electrolytic copper wire, diameter about 1 mm~2 mm, surface area 28.6 cm²±0.3 cm², wound into a spiral with outer diameter 2 cm and length 5 cm, must not be reused
Absorption liquid? 25 mL distilled water, with a few drops of phenolphthalein indicator
Titration solvent? Toluene and ethanol (95%) 3∶2 (volume ratio)
Concentration of potassium hydroxide-ethanol solution? 0.1 mol/L ethanol solution
Thermometer requirement? Conforms to thermometer No. GB—59 in GB/T 514
Test sample filtration? Dry glass filter (105 ℃ under 1 h) or 8 μm membrane filter; discard the first 25 mL of filtrate
Cleaning of vessels? Clean with acetone → rinse with water → soak in concentrated sulfuric acid for at least 16 h → rinse until acid-free → rinse thoroughly with water → bake at 105 ℃ for at least 3 h → cool in a desiccator
Precision? Repeatability r and reproducibility R are shown in Table 2; the values in Table 2 are not provided in the available source; requires confirmation against the source standard (source-text extraction)
Report chapter? Not provided in the available source (source-text extraction missing)
Annexes? Annex A normative (method for determining the maximum pore diameter of sintered glass filters); Annex B informative (clause number comparison)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.