Origin Standard

NB/SH/T 0852-2010 Determination of the viscosity-temperature relationship of in-service oils and soot-containing engine oils at low temperatures

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

A special rotational viscometer with a digital output computer program is used to analyze in-service oils and soot-containing engine oils. A glass stator and a metal rotor are attached to the viscometer; according to the temperature control program for calibration and sample analysis, and according to the stator and rotor pairing used during calibration, the test lubricating oil sample 20 mL is poured into the stator. It is preheated in a 90 ℃ preheater for 1.5 h to 2.0 h. After preheating is complete, the room-temperature rotor is connected to the stator tube containing the preheated oil, and then connected to the viscosity head with a torque sensor; the viscosity head has an adapter that allows the rotor to automatically position itself at the center of the stator during the test. The rotor speed is 0.3 r/min, and the cooling program of the sample cell starts from −5 ℃ and decreases at a rate of 3 ℃/h to the temperature at which the maximum torque can be recorded. After collecting the required information, the computer program generates the required viscosity and rheological values from the recorded data.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

Table 1 Procedure for obtaining calibration information with the liquid cooling bath (original table 1, source-text extraction is noisy, requires confirmation against the source standard (source-text extraction))

Step Temperature/℃ Time
1 −5 Indeterminate, non-critical time
2 −5 Indeterminate, non-critical time
3 −10 30 min
4 −15 30 min
5 −20 30 min
6 −25 30 min
7 −30 30 min
8 −33 30 min
9 −35 30 min
10 −5 Indeterminate, non-critical time

(In the original table 1, the correspondence between the text such as "cool to −5 hold/set data acquisition and start program/acquire data/cool to −10 ℃ and hold..." and the temperature column has a misalignment of source-text extraction, requires confirmation against the source standard (source-text extraction))

Table 2 Procedure for obtaining test oil information with the liquid cooling bath (original table 2, source-text extraction is noisy, requires confirmation against the source standard (source-text extraction))

Method Temperature/℃ Time
Cooling bath stabilized at −5° −5 Indeterminate, non-critical time
Data acquisition and start program −5 Indeterminate, non-critical time
Temperature reaches 40000 mPa·s −5 to −40 3 ℃/h
— — Uncertain, non-strict time

7. Sampling and Specimen Preparation

8. Analytical Procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

Judge the reliability of the test results according to the following provisions (95% confidence level).

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A Reference

Question Key Answer Points
What does this standard measure? The apparent viscosity of in-service engine oils or engine oils containing soot at low temperature, and gives viscosity, gel index, and gel index temperature (1.1, 1.3).
Applicable temperature range and cooling rate? −5 ℃~−40 ℃, cooled at 3 ℃/h (1.2).
Shear conditions? Shear stress below 200 Pa, shear rate approximately 0.25 s⁻¹ (1.2, unit requires confirmation against the source standard (source-text extraction)).
Sample amount? About 20 mL (8, Chapter 4).
Preheating conditions? 90 ℃ ± 2 ℃, 1.5 h~2.0 h (Chapter 4); 12.2.2 is 90 min~120 min.
Rotor/stator dimensions? Rotor length 65.5 mm ± 0.1 mm, diameter 18.40 mm ± 0.02 mm; stator diameter 22.05 mm ± 0.02 mm (6.1.1, 6.1.2).
Rotor speed? Uniform 12 r/min maintained at 10 min, test 0.3 r/min (13.9).
Dry gas flow rate? About 10 mL/min (13.8); during calibration 10 mL/min~20 mL/min.
Which viscosities correspond to temperatures to be reported? 5000, 15000, 25000, 40000, 60000 mPa·s (14.1).
Gel index formula? GI = −[(log log η₁) − (log log η₂)]/(log T₁ − log T₂) (3.16 formula 2).
Critical temperature repeatability/reproducibility? r ≤ 1.1 ℃, R ≤ 1.4 ℃ (15.1).
Gel index repeatability/reproducibility? r ≤ of the average value 11%, R ≤ of the average value 27% (15.2).
Gel index temperature repeatability/reproducibility? r ≤ 0.7 ℃, R ≤ 2.8 ℃ (15.3).
Viscosity repeatability/reproducibility? r ≤ of the average value 8%, R ≤ 14% (15.4).
Bias? Because there is no applicable reference material, the bias cannot be determined (15.5, clause number suspected duplicate, requires confirmation against the source standard (source-text extraction)).
Which method standards are cited? GB/T 4756, GB/T 8023, GB/T 9171, SH/T 0562 (Chapter 2).
Adoption relationship? Modified adoption of ASTM D7110-05a (Foreword).

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.