NB/SH/T 0879-2014 Determination of boiling range distribution of residual-containing oil samples — High-temperature gas chromatography

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

Applicable:

Not applicable:

Supplementary notes:

3. Method principle

In this gas chromatographic method, both the inlet and the capillary column use programmed temperature. A flame ionization detector is used as the sensor to convert mass into an electronic signal. The data acquisition system acquires the signal in slice mode and uses chromatography software to accumulate the signal. The retention time calibration standard is measured to obtain the curve of retention time versus boiling point. The reference oil solution is used to determine the detector response factor (the source text here has source-text extraction noise, suspected to be "detector response factor"). Because the reference oil can completely flow out under the chromatographic conditions in this standard. Solvent injection is performed, and the resulting signal is subtracted from the blank and sample chromatographic results. Finally, the sample solution is injected and the response factor is applied to calculate the sample recovery and, after converting the sample retention time to temperature, calculate the boiling range distribution within the recovered amount.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

Table 1 Chromatographic operating conditions:

Item Condition 1ᵃ Condition 2ᵇ
Initial column oven temperature/°C -20 35
Initial column oven temperature hold time/min 0 (source text source-text extraction requires confirmation) 0 (source text source-text extraction requires confirmation)
Column oven program rate/(°C/min) 15 15
Final column oven temperature/°C 425~435 430
Final column oven temperature hold time/min 10 10
Initial inlet temperature/°C 50 50
Inlet program rate/(°C/min) 15 15
Final inlet temperature/°C 425 430
Chromatographic column 5 m × 0.53 mm × 0.15 μm PDMS 10 m × 0.53 mm × 0.15 μm PDMS
Column flow rate/(mL/min) 20 20
Flow control Constant flow Constant flow
Detector Flame ionization detector Flame ionization detector
Detector temperature/°C 435 435
Detector gas: hydrogen/(mL/min) 40 40
Detector gas: air/(mL/min) 450 450
Detector gas: auxiliary gas (N2, He)/(mL/min) 15 15
Injection volume/μL 0.2~1.0 0.2
Sample mass fraction/% 2.0 2.0
Data acquisition frequency/Hz 10 10
Total acquisition time/min 40~50 30~40

ᵃ Recommended operating conditions for crude oil. ᵇ Operating conditions for crude oil and residual oil.

Other conditions:

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

Table 4 Repeatability and reproducibility of residual oil (shall not be extrapolated):

Yield/% Repeatability/°C Reproducibility/°C Coverage range/°C
IBP 5.72 13.7 246~504
5 3.39 5.75 315~547
10 3.19 5.39 346~563
15 2.88 5.2 368~575
20 3.42 6.5 388~585
25 3.55 6.71 405~595
30 3.93 7.6 420~604
35 4.38 8.9 434~614
40 5.22 11 447~624
45 6.27 13.5 462~634
50 7.18 16.4 477~645
55 8.64 19.9 493~656
60 10.1 22.6 509~670
65 11.7 24.7 529~684
70 15.2 27.4 550~699
75 16.6 30.9 574~716

Table 5 Repeatability and reproducibility of crude oil (shall not be extrapolated):

Yield/% Repeatability/°C Reproducibility/°C Coverage range/°C
IBP 1.35 2.49 30~31
5 8.94 19.6 76~97
10 11.4 19.5 109~154
15 8.23 15.1 134~217
20 7.51 13.1 160~259
25 8.7 13.6 184~295
30 8.22 13.1 210~327
35 8.52 14.0 231~358
40 8.83 14.9 249~398
45 8.99 15.1 265~436
50 9.88 16.4 285~325 (requires confirmation against the source standard source-text extraction)
55 10.8 18.6 304~517
60 12.4 21.5 326~563
65 13.8 24.3 351~608
70 14.3 21.2 379~608
75 15.1 28.24 410~700

Table 6 Repeatability and reproducibility of cut intervals (X is the mass yield of the cut, shall not be extrapolated):

Fraction Cut temperature/°C Repeatability/% Reproducibility/%
Crude oil cut 1 82.2 1.24 1.74
Crude oil cut 2 193.3 1.42 1.92
Crude oil cut 3 248.9 1.48 2.05
Crude oil cut 4 343.3 1.63 2.28
Crude oil cut 5 426.7 1.78 2.58
Crude oil cut 6 565.6 2.1 3.03
Crude oil cut 7 596.1 2.03 3.12
Crude oil cut 8 720 2.52 3.17
Residual oil cut 1 330 0.0748X 0.126X
Residual oil cut 2 450 0.0767X 0.109X
Residual oil cut 3 600 0.0338(X+30) 0.0726(X+30)
Residual oil cut 4 720 5.36 7.16

11. Report

Report temperatures at intervals of every 1% from 1% to the integer range of recovery, accurate to 0.5 °C. Report the initial boiling point (IBP). Report the selected cut intervals.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer
What samples does this standard apply to? Crude oil and residual oils (atmospheric residuum, vacuum residuum) and other residual-containing oil samples that cannot flow completely
Upper limit of measurable boiling range? 720 °C (equivalent to n-C100 elution temperature)
What is it not applicable to? Boiling range distribution in the interval C4~C5; oil samples containing complex compounds such as polyesters and polyolefins
What detector is used? Flame ionization detector (FID)
What is the carrier gas? Helium, column flow rate 20 mL/min
Column specifications? Inner diameter 0.5 mm, film thickness 0.09~0.17 μm, bonded 100% dimethylpolysiloxane (PDMS)
What are the initial column oven temperatures for crude oil and residual oil respectively? Crude oil -20 °C; residual oil and high IBP samples 35~40 °C
Detector temperature requirement? At least 5~10 °C higher than the maximum column temperature
Injection volume? 0.1 μL~0.2 μL (autosampler)
Data acquisition frequency? 10 Hz (0.1 s slice width)
What is the solvent? Carbon disulfide (CS2), purity greater than 99%
What is the reference oil? 5010, HTSD
What quenching factor is used? 1.93 (interlaboratory study value)
Which samples require quenching correction? Samples containing components that co-elute with the solvent (such as crude oil); residual oil or reference oil does not require it
How is the recovery threshold handled? If RC ≤ threshold, use the measured value; if RC > threshold, set to 100%; if RC > 102%, repeat the analysis
Resolution requirement? 1.8~4.0
Peak asymmetry requirement? 0.8~1.2
Relative response factor requirement? 0.95~1.05
Reporting temperature interval and precision? Every 1% interval, accurate to 0.5 °C
Is bias determined? Not determined (boiling range distribution is defined only in this method)
Relationship with ASTM D7169-11? Modified adoption using the redrafting method
What is Annex A? Normative annex, detailed hydrocarbon analysis of light components in crude oil
What is Annex B? Normative annex, chromatographic separation and chromatograms

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.