Origin Standard

NB/SH/T 0912-2015 Engine bench test oil 100℃ kinematic viscosity determination method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After thoroughly mixing the in-service oil sample, under strictly controlled temperature, measure the time for the sample to flow through a Fenske reverse-flow viscometer under gravity; the product of the flow time and the viscometer constant is the kinematic viscosity of the sample 100℃.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

11. Report

The report shall include the following information:

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick-reference Q&A

Question Key points of answer
What is the method number of this standard? NB/SH/T 0912—2015
What is the Chinese title of the standard? Determination of kinematic viscosity of engine bench test oils 100℃
What viscometer is used? Fenske reverse-flow capillary viscometer, size designation 200, or other Fenske reverse-flow viscometers conforming to ISO 3105 / ASTM D446 / SH/T 0173—1992
What samples are applicable? Engine bench test oils containing soot
What is the test temperature? 100℃
What are the temperature control requirements for the constant-temperature bath? The difference from the set temperature shall not exceed ±0.02℃
What is the viscometer equilibration time? 15 min±30 s
What is the timing accuracy requirement? Accurate to 0.1 s or better; when 15 min, the reading accuracy is within ±0.07%
What is the calculation formula? ν = C·t
To how many places is the result retained? The 2th decimal place
What is the test time limit requirement? Completed within one month after the engine test ends; research test samples are not subject to this restriction
What is the applicable range of precision? In-service engine oil samples with kinematic viscosity 100℃ 12 mm²/s~43 mm²/s
Repeatability formula? 0.0322×e^(0.086r) (the source text source-text extraction is as such, requires confirmation against the source standard (source-text extraction))
Reproducibility formula? 0.0349×e^(0.1327) (the source text source-text extraction is as such, requires confirmation against the source standard (source-text extraction))
Is there a fixed reference oil? No; when needed, the CEC SG-L-083 working group can provide reference oils
Which foreign standard is modified and adopted? CEC L-83-97 “Determination of kinematic viscosity of in-service oils 100°”
Is this the first release? Yes, this standard is released for the first time

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.