Origin Standard

NB/SH/T 0904-2015 Determination of Oxidation Stability of Automatic Transmission Fluids

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Immerse steel and copper catalysts and a glass rod in the test oil, and stir the test oil at a temperature of 150 ℃ for 96 h to oxidize it. Measure the kinematic viscosity and acid value of the oxidized oil and compare them with the unoxidized oil, and calculate the viscosity ratio and the change in acid value. At the same time, observe the adhesion state of lacquer-like substances or sludge on the glass rod. (Note: This paragraph in the original text has heavy source-text extraction noise, and individual words require confirmation against the source standard (source-text extraction).)

4. Reagents and materials (purity / preparation)

4.1 Reagents

4.2 Materials

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis procedure

9. Qualitative and quantitative determination and calculation formulas

9.1 Viscosity ratio

9.2 Acid value increase

Calculate the difference in acid value of the test oil before and after oxidation, retaining three significant figures. However, when it is less than 1 mgKOH/g, retain two decimal places. When the difference between the two test results does not exceed the tolerance in Table 1, the average of the two test results is recorded as the acid value increase. When the difference between the two test results exceeds the tolerance in Table 1, the group of tests is considered invalid.

Table 1 Tolerance values

Acid value increase/(mgKOH/g) Tolerance/(mgKOH/g)
0.05~1.0 0.3
Above 1.0~5.0 1
Above 5.0~20 4

9.3 Adhesion degree

Table 2 Classification standard for adhesion degree

Adhesion degree Summary
No adherent substance It is determined that there is no adherent substance on the glass rod, or the degree of coloration of the glass rod is less than colorimeter level 1
Adherent substance (thin) The degree of coloration of the glass rod conforms to colorimeter levels 1~2
Adherent substance (medium) The degree of coloration of the glass rod conforms to colorimeter levels 3~5
Adherent substance (thick) The degree of coloration of the glass rod conforms to colorimeter levels 6~9

10. Precision

11. Report

The test result report shall at least include the following contents:

12. Reference documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A reference

Question Key points of answer
What does this standard apply to? Evaluation of oxidation stability of automatic transmission fluid and related lubricating oil products.
What is the test temperature? 150.0 ℃±0.5 ℃.
What is the test time? 96 h.
What is the stirring speed? 1300 r/min±15 r/min, with the direction being the blades pressing down on the test oil.
What is the amount of test oil used? 250 mL per oil storage beaker.
What material is the catalyst? Steel (Q195 or Q215), copper (T2).
How is the viscosity ratio calculated? R = D2 / D1, where D1 is the kinematic viscosity of unoxidized oil at 40 ℃, and D2 is the kinematic viscosity of oxidized oil at 40 ℃, retaining two decimal places.
What is the precision requirement for viscosity ratio? The difference between the two results shall not exceed 14% of the average; otherwise, the group of tests is invalid.
How to look up the tolerance for acid value increase? According to Table 1: 0.05–1.0 tolerance 0.3; above 1.0–5.0 tolerance 1; above 5.0~20 tolerance 4 (mgKOH/g).
How many levels does adhesion degree have? The color comparison card is divided into 9 levels; the adhesion state is divided into four categories: no adherent substance, thin, medium, and thick.
What to do if the two adhesion degree results are inconsistent? Take the side with the larger color number in the color comparison card as the result.
According to what standard is kinematic viscosity measured? GB/T 265, measuring kinematic viscosity at 40 ℃.
According to what standard is acid value measured? GB/T 7304 potentiometric titration method.
Can one oil storage beaker be used for testing? It can be used when the difference in viscosity ratio, difference in acid value, and adhesion degree are all known to meet the specified conditions, and the result is taken from one test oil result.
What shall the report at least include? Laboratory information and test date, application of this standard, name of the test oil, results of Chapter 9, special matters.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.