Origin Standard

SH/T 0125-1992 Liquefied petroleum gas hydrogen sulfide test method (lead acetate method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Under specified conditions, the vaporized sample is passed through a moistened lead acetate test strip; hydrogen sulfide reacts with lead acetate to form lead sulfide (the source text gives "lead sulfide error", requires confirmation against the source standard (source-text extraction)), thereby causing the test strip to change color; the degree of color change goes from yellow to black as the amount of hydrogen sulfide present increases.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

Not provided in the available source.

11. Report

Report as "present" or "absent" hydrogen sulfide.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick-reference Q&A

Question Key answer
What method is this standard? Liquefied petroleum gas hydrogen sulfide test method (lead acetate method), qualitatively determining the presence or absence of hydrogen sulfide.
Standard number and year? SH/T 0125-92; approved on 1992-05-20, implemented on 1992-05-20.
Which international standard is equivalently adopted? ISO 8819—1987.
Which standard does it replace? From the date of implementation, the former GB 11125-89 is void.
What is the lower detection limit? 4 mg/m³ (the source text gives 4mg/m’, requires confirmation against the source standard (source-text extraction)).
What sample is applicable? Detection of hydrogen sulfide in liquefied petroleum gas.
What substances interfere? Methyl mercaptan produces a transient yellow stain, but it completely disappears before 5 min; other sulfides do not interfere.
What is the method principle? The vaporized sample passes through a moistened lead acetate test strip; hydrogen sulfide reacts with lead acetate to form lead sulfide, causing the test strip to change color from yellow to black.
What is the lead acetate purity requirement? Analytical reagent grade, content not less than 99.0%.
How is the test strip prepared? A smooth filter paper strip is soaked in 50 g/L lead acetate solution, then removed and excess solution is removed with clean filter paper.
What are the test strip specifications? Length 51 mm, width 9.5 mm, with a circular hole of diameter 3.5 mm near the middle of one end.
What flowmeter is used? A wet test meter or a rotameter, with a flow range of 2~3 L/min.
What is the water temperature requirement? 60~80℃.
Gas flow rate? 2.3±0.2 L/min.
Exposure time? Exactly 2 min.
How is the test strip moistened? Moisten with distilled water.
Flushing time? About 1 min.
How is absence of hydrogen sulfide determined? No obvious color difference between the exposed and unexposed moistened test strips.
How is presence of hydrogen sulfide determined? There is an obvious color difference, and an obvious color is still retained after waiting for 5 min.
How is presence of methyl mercaptan determined? An obvious yellow color appears initially, but it does not retain until after 5 min.
How is the report written? Report as "present" or "absent" hydrogen sulfide.
What should be noted in sampling? It is desirable to connect the apparatus directly to the sample source and test on site; avoid transferring to a sampler, as laboratory data are unreliable.
Why avoid rubber hoses/rubber stoppers? Hydrogen sulfide has an affinity for rubber, which can produce erroneous results.
Is precision specified? Not provided in the available source.
Is there a quantitative calculation formula? Not provided in the available source (this method is qualitative).