Origin Standard

SH/T 0172-2001 Determination of sulfur content in petroleum products (high-temperature method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formulas

10. Precision

11. Report

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference for questions and answers

Question Key points of answer
What is the method number of this standard? SH/T 0172-2001
Which standard does it replace? SH/T 0172-92
Which foreign standard is equivalently adopted? ASTM D1552-95
How many determination methods are there? Three: electric induction furnace + iodate, resistance furnace + iodate, resistance furnace + infrared detection
Applicable sulfur content range? Not less than 0.06%(m/m), petroleum coke can be as high as 8%(m/m)
Applicable boiling point? Higher than 177℃
Chlorine interference limit for the iodate system? No interference when the chlorine content is lower than 1%(m/m)
Nitrogen interference limit for the iodate system? Interference may occur when the nitrogen content exceeds 0.1%(m/m)
Minimum temperature of the combustion zone of the electric induction furnace? At least 1482℃
Minimum temperature of the resistance furnace? At least 1371℃
Operating temperature of the resistance furnace? 1316℃±14℃
Furnace temperature of the infrared system? 1371℃
Oxygen flow rate of the electric induction furnace? 1L/min±0.05L/min
Oxygen flow rate of the resistance furnace? 2L/min±0.1L/min
Alum factor range? 1.02~1.08
Approximately what is the sulfur conversion rate? About 97%
Precision of reported results? 0.05%~5.00% to the nearest 0.01%(m/m); 5%~30% to the nearest 0.1%(m/m)
Repeatability formula for petroleum coke? r = 0.05X₁
Reproducibility formula for petroleum coke? R = 0.22X₂
Sampling reference standard? GB/T 4756
Water reference standard? GB/T 6682 Grade 3 water
Absorber reference standard? GB/T 11131
Where is the preparation of sulfur standard samples found? Annex A (informative annex)
Is the bias determined? Being determined

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.