Origin Standard

SH/T 0185-1992 Determination of Oxidation Stability of Straight-run Lubricating Oils

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Place two oxidation tubes containing the test sample (one without catalyst, the other with copper catalyst) into a heating bath at a temperature of 120℃ and pass oxygen through for 48h. Volatile acids are blown out by the flowing oxygen and absorbed by water. After oxidation is completed, the volatile acid value, soluble acid value, and sediment content in the oil need to be determined. Oxidation stability is expressed as the percentage of total oxidation products.

4. Reagents and materials (purity / preparation)

4.1 Materials

4.2 Reagents

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analysis procedure

9. Qualitative and Quantitative Determination and Calculation Formulas

10. Precision

The following provisions are used to judge the reliability of test results (95% confidence level).

Precision table:

Item Repeatability Reproducibility R
Total oxidation products (without catalyst), % (m/m) 0.217(X+0.05) 0.695(X+0.05)
Total oxidation products (with catalyst), % (m/m) 0.19 0.33
Ratio of precipitate to total oxidation products (with catalyst), % 0.080(X+22) 0.268(X+22)

Note: X represents the average of two results.

11. Report

Take the arithmetic mean of two results from repeated determinations as the total oxidation products of the sample without catalyst and with copper catalyst, and the ratio of precipitate to total oxidation products with copper catalyst.

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key Answer Points
Standard number and name? SH/T 0185-92 Determination of oxidation stability of straight-run lubricating oils
What standard does it replace? ZB E34 001-86
What oils are applicable? Straight-run and additive-free lubricating oils
Oxidation temperature? 120℃±0.5℃
Oxygen flow time? 48h
Oxygen flow rate? 1.0L/h±0.1 L/h, verified daily
Sample amount? 25g±0.04g
Catalyst? Copper wire coil, purity 99.9%, meeting the requirements of No. 12 in GB 5231
Absorption liquid? 25mL distilled water or ion-exchange water + 5–6 drops of phenolphthalein-ethanol indicator solution
Standing conditions after oxidation? Stand in the dark at 20℃±2℃ for 24h
Which items are determined? Volatile acid value, soluble acid value, precipitate content in oxidized oil
How is oxidation stability expressed? Percentage of total oxidation products
Formula for total oxidation products? TOP = X2 + 180(X1 + X3) / 561
Precision condition? 95% confidence level
Report result? Take the arithmetic mean of two results from repeated determinations
Reference adoption? IP 306/82

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.