Origin Standard

SH/T 0231-1992 Determination of hydrogen sulfide content in liquefied petroleum gas (chromatographic method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Load coarsely porous silica gel impregnated with lead acetate into a glass reaction tube. When the gas sample passes through the silica gel layer, hydrogen sulfide reacts with lead acetate to form black lead sulfide, causing a stained layer of a certain length to appear on the silica gel layer. Determine the amount of hydrogen sulfide that passed through the reaction tube based on the volume of stained silica gel, and then calculate the hydrogen sulfide content in the sample based on the measured sample volume.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

11. Report

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A reference

Question Key answer points
Standard number and replacement relationship? SH/T 0231-92, replaces SY 2082-85.
What samples are applicable? Liquefied petroleum gas.
Measurement range? Hydrogen sulfide 5~500 mg/m³.
Method principle? Coarse-pore silica gel impregnated with lead acetate reacts with hydrogen sulfide to form a black lead sulfide stained layer, calculated according to the volume of stained silica gel and the sample volume.
Reaction tube specifications? The lower end has a porous glass partition; 1 mL tube minimum graduation 0.01 mL, 2 mL tube minimum graduation 0.02 mL.
Sampler requirements? Can hold about 5 g of liquefied petroleum gas; each must pass a 4 MPa (40 kgf/cm²) hydrostatic test.
Moisture requirement for impregnated silica gel? 65±3℃ dried to moisture content 25~35%.
Repeatability requirement? At 5~10 mg/m³, the difference between two results shall not be greater than 2 mg/m³; when greater than 10 mg/m³, not greater than 20% of the smaller result.
Reproducibility? Not determined.
Result value? Take the arithmetic mean of the two repeated determination results.
What else should be recorded in the report? Indoor temperature and atmospheric pressure.
Drafting unit? Luoyang Petrochemical Engineering Company Refining Research Institute; main drafter Li Yushu.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.