SH/T 0237-1992 Determination of Storage Stability of Gasoline

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

A certain volume of sample is stored at 93℃ for 16h, and its oxygen absorption and total gum formed (the sum of actual gum and sediment) are determined, with the storage stability expressed by the instability index (BZ16) value. The smaller the BZ16 value, the better the storage safety of the sample. It also has a certain correspondence with the results of the 43℃ and room-temperature storage tests.

4. Reagents and materials (purity / preparation)

4.1 Materials

4.2 Reagents

5. Apparatus and equipment

6. Recommended operating conditions

6.1 Storage conditions

6.2 Appendix A Gas chromatography operating conditions

6.3 Appendix B 43℃ storage test conditions

7. Sampling and sample preparation

8. Analysis steps

8.1 Pre-test determination (6.2)

Determine the filtered sample separately:

8.2 Storage test (6.3–6.6)

8.3 Post-test determination (6.7–6.8)

8.4 Appendix A Determination of oxygen content in the reserved space of the test bottle

9. Qualitative and quantitative and calculation formulas

9.1 Sediment calculation (formula 1)

The sediment X (mg/100mL) of the sample is calculated according to formula (1):

9.2 Calculation of instability index BZ16 (formula 2)

The instability index BZ16 of the sample is calculated according to formula (2):

9.3 Appendix A Calculation of oxygen content (formula A4)

The oxygen content O16 [%(V/V)] in the reserved space of the test bottle is calculated according to formula (A4):

9.4 Appendix C Prediction of 43℃ storage test results using BZ16 value (formula C1)

For a sample stored under 43℃ for a certain time, the total gum content m43 (mg/100mL) in the test is calculated according to formula (C1):

10. Precision

Repeatability: The difference between two results of repeated determinations by the same operator and their arithmetic mean shall not exceed the following values.

BZ16 (based on mean) Repeatability
≤0.1 0.02
>0.1–1.0 0.2
>1.0–10.0 1.5
>10.0 2.0

11. Report

Take the arithmetic mean of two results of repeated determinations as the test result.

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference Q&A

Question Key answer
What does this standard apply to? Gasoline.
What index is used to express storage stability? Instability index BZ16 value.
Is a larger or smaller BZ16 value better? The smaller the better; the smaller the BZ16 value, the better the storage safety of the sample.
What are the storage temperature and time? 93℃ ± 0.5℃, 16h.
What is the sample amount? 130mL.
How many parallel sample bottles are stored each time? Two bottles.
What items need to be determined before the test? Existent gum (GB/T 509), acidity (GB/T 258), light transmittance (72 spectrophotometer, reference liquid distilled water, wavelength 420nm, 1cm cuvette).
What does total gum include? The sum of existent gum and sediment.
When the sediment exceeds how much must it be determined according to clause 6.7? When the contained sediment is considered to exceed 1mg/100mL.
What detector is used for oxygen content determination? Thermal conductivity detector.
What is the stationary phase of the chromatographic column? 40–60 mesh 13X molecular sieve, activated at 550℃ for 3h before packing.
What is the carrier gas? What is the flow rate? Hydrogen, 40–50mL/min.
What are the column temperature and bridge current? Column temperature 50℃; bridge current 180mA.
When O16 is greater than what, the term O0−O16 is taken as 1.0%(V/V)? When greater than 20.0%(V/V).
What is the allowable difference when repeatability BZ16 ≤0.1? 0.02.
What is the allowable difference when repeatability BZ16 >10.0? 2.0.
How is the test result reported? Take the arithmetic mean of two results of repeated determinations.
How much is stored per bottle in the 43℃ storage test? 170mL.
What is the temperature control of the storage room in the 43℃ storage test? 43℃ ± 2℃.
How often is the gas changed in the 43℃ storage test? Every 4 weeks.
When the sample loss in the 43℃ storage test is greater than what is it discarded? Greater than 15% of the original total sample volume.
What is the constant C for predicting total gum in 43℃ storage? 1.2.
What is the m value corresponding to 43℃ storage for 8 weeks? 0.23.
What is the m value corresponding to 43℃ storage for 16 weeks? 0.78.
What is the m value corresponding to 43℃ storage for 32 weeks? 9.15.
Which standard does this standard replace? SY 2124-82.
In what year was this standard first issued? 1977.
Which unit is responsible for drafting this standard? Refining Research Institute of Luoyang Petrochemical Engineering Company.
Who is the main drafter of this standard? Zhang Guanglin.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.