Origin Standard

SH/T 0452-1992 Lubricating grease storage stability test method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After the lubricating grease has been stored under specified conditions, its consistency (unworked and worked penetration) is measured, and the penetration values before and after storage are compared. Note: In lubricating grease specifications that cite this method, the storage time and temperature for the storage test of that grease must be given.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and specimen preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

Not provided in the available source.

11. Report

Report the change in penetration of the specimen before and after storage to evaluate the storage stability of the specimen.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick-reference Q&A

Question Key answer
What are the method number and name of this standard? SH/T 0452-92 Lubricating grease storage stability test method
Which old standard does it replace? SY 4028-84
Has it been confirmed? Confirmed in 2004
What is the scope of application? Determining the stability of lubricating grease after storage for a certain period under elevated temperature conditions
What is the method principle? After storage under specified conditions, measure consistency (unworked and worked penetration), and compare penetration values before and after storage
How are storage temperature and time determined? Given by the lubricating grease specification that cites this method; the standard text does not list specific values
What material is used to cover the specimen? Aluminum foil (commercially available)
What main apparatus are needed? Two standard grease cups, grease worker, penetrometer (see GB/T 269), natural convection constant-temperature oven
What is the specimen amount? About 1 kg, sufficient to fill two standard grease cups
To what temperature is it cooled after storage? Cool to 25℃ (original text "259C", requires confirmation against the source standard (source-text extraction))
According to which standard is penetration determined? GB/T 269
How are the results expressed? Report the change in penetration before and after storage to evaluate storage stability
Is precision specified? Not provided in the available source
Which foreign method is equivalently adopted? United States Federal Test Method Standard FS 791 c3467.1(1986)
Drafting organization and drafter? Drafted by Sinopec Yiping Chemical Plant; drafter Liu Qinghe

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.