SH/T 0453-1992 Test method for water resistance and water-ethanol (1:1) solution) performance of lubricating grease
AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.
Card type: Test method
1. Method number / full name / English name / replacement relationship
- Method number: SH/T 0453-92
- Full name: Test method for water resistance and water-ethanol (1:1) solution) performance of lubricating grease
- English name: not provided in the available source
- Replacement relationship: replaces SY 4029-84
- Other: confirmed in 2004; identically adopts the United States Federal Test Method Standard FS 791 C (54150986) "Test method for water resistance and water-ethanol (1:1) solution) performance of lubricating grease"
2. Scope of application and non-applicability
- Scope of application: This standard is applicable to determining the performance of lubricating grease against the dissolving action of water and water-ethanol (1:1) solution).
- Not applicable: not provided in the available source
3. Method principle
Divide the sample into two portions, place one portion in distilled water and the other in water-ethanol solution, and after one week inspect the samples for disintegration.
4. Reagents and materials (purity / preparation)
- 95% Ethanol: chemically pure, conforming to GB/T 679
- Distilled water: specification not stated in the source text
- Water-ethanol solution: ethanol-distilled water volume ratio 1:1
5. Apparatus and equipment
- Glass container: 250 mL, stoppered, two
6. Recommended operating conditions
- Temperature: room temperature
- Standing time: one week
- Other: not provided in the available source
7. Sampling and sample preparation
- Sample about 4 g
- Small grease portions separated from the sample, each about 2 g
8. Analytical procedure
7.1 Pour 200 mL distilled water into one glass container, and pour 200 mL ethanol-distilled water (volume ratio 1:1) into another glass container. 7.2 Place the two sample portions (small grease portions separated from the sample, each about 2 g) respectively into the two containers, firmly stopper the containers, and let stand at room temperature for one week. 7.3 After one week, shake the containers once or twice, then visually inspect the degree of disintegration of the sample in each container.
9. Qualitative and quantitative determination and calculation formula
- Qualitative and quantitative method: visual inspection of the degree of disintegration of the sample in each container
- Calculation formula: not provided in the available source
10. Precision
not provided in the available source
11. Report
Report the degree of disintegration of the lubricating grease sample in each container.
12. Referenced documents
- GB/T 679 Chemical reagent Ethanol (95%)
- FS 791 C (54150986) "Test method for water resistance and water-ethanol (1:1) solution) performance of lubricating grease" (identically adopted)
13. Source and verification
This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.
14. Quick reference Q&A
| Question | Key answer points |
|---|---|
| What is the standard number? | SH/T 0453-92 |
| Which standard does it replace? | SY 4029-84 |
| Does it identically adopt a foreign standard? | Identically adopts FS 791 C (54150986) |
| What performance is it applicable to test? | The performance of lubricating grease against the dissolving action of water and water-ethanol (1:1) solution) |
| What is the method principle? | Two sample portions are respectively placed in distilled water and water-ethanol solution, and after one week the disintegration phenomenon is inspected |
| What reagent is used? | 95% Ethanol, chemically pure, conforming to GB/T 679 |
| What is the water-ethanol solution ratio? | Ethanol-distilled water volume ratio 1:1 |
| What container is used? | 250 mL stoppered glass containers, two |
| How much sample is used? | Sample about 4 g; each small grease portion about 2 g |
| How much of each solution is added? | Distilled water 200 mL; ethanol-distilled water (1:1) 200 mL |
| What are the standing conditions? | Room temperature, firmly stoppered, let stand for one week |
| What is done after one week? | Shake once or twice, visually inspect the degree of disintegration |
| How is the result expressed? | Report the degree of disintegration of the lubricating grease sample in each container |
| Is precision specified? | not provided in the available source |
| Is there a calculation formula? | not provided in the available source |
| Drafting unit? | Sinopec Yiping Chemical Plant |
| Drafter? | Liu Qinghe |
| Approval and implementation dates? | Both are 1992-05-20 in the source text (requires confirmation against the source standard source-text extraction) |
Related public products
Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.
Search related productsSource and review status
This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.