SH/T 0561-1993 Determination of thermal decomposition temperature of antioxidant and anti-corrosion additives (capillary method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Inject the sample into a capillary tube of a specified size, heat it under specified conditions, and measure the lowest temperature at which the sample changes into a white crystalline substance; this is the thermal decomposition temperature of the sample.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

10. Precision

Judge the reliability of the test results according to the following provisions (95% confidence level).

11. Report

Take the arithmetic mean of two results from repeated determinations and round to an integer as the determination result.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference Q&A

Question Key answer
What is the method number of this standard? SH/T 0561-93.
What does this standard apply to? Antioxidant and anti-corrosion additives.
What is the method principle? Inject the sample into a capillary tube, heat under specified conditions, and measure the lowest temperature at which the sample changes into a white crystalline substance.
What thermometer is used? An open-cup flash point thermometer of number 1 as specified in GB/T 514.
Capillary tube specifications? Length 80 mm±1 mm, inner diameter 1.5 mm±0.1 mm, one end sealed, wall thickness about 0.15 mm, hard glass.
Sample injection amount? Liquid layer height in the capillary tube 5~6 mm.
How far is the bottom of the thermometer mercury bulb from the bottom of the test tube? 8~10 mm.
How far is the bottom of the test tube from the bottom of the beaker? 15~20 mm.
What is the requirement for the silicone oil level in the beaker? At least 10 mm higher than the methyl silicone oil level in the glass test tube.
How is the heating rate controlled? At 20℃ before the expected thermal decomposition temperature, control at an increase of 2~3℃ per minute.
To what value is the temperature read? Read to 0.5℃.
Repeatability requirement? For the same operator and same laboratory, the difference between two results shall not be greater than 3℃.
Reproducibility requirement? For different operators and different laboratories, the difference between two results shall not be greater than 4℃.
How are results reported? Take the arithmetic mean of two results from repeated determinations and round to an integer.
What are the referenced standards? GB/T 514.