SH/T 0568-1993 Determination of Storage Stability of Water-in-Oil Emulsions (Oven Method)
AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.
Card type: Test method
1. Method number / full title / English name / replacement relationship
- Standard number: SH/T 0568-93
- Full title: Determination of Storage Stability of Water-in-Oil Emulsions (Oven Method)
- English name: not provided in the available source
- Replacement relationship: not provided in the available source
- Other: confirmed in 2004; reference adoption of ASTM D3707-89 "Determination of Storage Stability of Water-in-Oil Emulsions (Oven Method)"
- Approval/implementation: approved by China Petrochemical Corporation 1993-08-19, implemented on 1994-05-01
2. Scope of application and non-applicability
- This standard specifies a method for determining the storage stability of water-in-oil emulsions.
- This standard applies to water-in-oil emulsions.
- Not applicable: not provided in the available source.
3. Method principle
Take a 100 mL test sample, place it in an oven at 85℃±1℃, and keep it at constant temperature for 48 h or 96 h. Then determine its oil separation amount [%(V/V)], water separation amount [%(V/V)], and the water content [%(m/m)] in the upper and lower test samples at the specified positions.
4. Reagents and materials (purity / preparation)
not provided in the available source.
5. Instruments and equipment
- 5.1 Oven: with forced air circulation, temperature controlled at 85℃±1℃.
- 5.2 Graduated cylinder: 100 mL, with graduations of 1 mL, with a ground-glass stopper. The stopper shall have a vent groove.
- 5.3 Pipette: 10 mL.
- 5.4 Microsyringe: 0.5 or 1 μL.
- 5.5 Narrow-mouth glass bottle: about 30 mL.
- 5.6 Rubber bulb.
6. Recommended operating conditions
- Oven temperature: 85℃±1℃.
- Constant-temperature time: 48 h or 96 h.
- Placement position of the graduated cylinder: place in the middle of the oven and at least 75 mm from the bottom of the oven to ensure uniform heating.
- Standing at room temperature after the test: stand at room temperature (21℃±3℃) for 1 h.
- Sampling positions: the upper test sample is taken at the 80 mL mark of the graduated cylinder; the lower test sample is taken at the 15 mL mark of the graduated cylinder.
7. Sampling and test sample preparation
- Place the sample into a container of 1 L or 500 mL, and shake vigorously by hand or mix mechanically for 3~5 min to ensure the sample is uniform.
- Note: A water-in-oil emulsion is a two-phase system, unlike a completely homogeneous system; therefore, it is difficult to mix in a large container and to withdraw a representative test sample. The best method for obtaining a uniform liquid is continuous, vigorous mechanical stirring. However, for unstable emulsions that have been stored for more than half a year, this sampling method also cannot obtain a representative test sample.
8. Analytical procedure
- 7.1 Measure 100 mL of test sample with a graduated cylinder, and cover it.
- 7.2 Place the graduated cylinder in an oven maintained at 85℃±1℃, and leave it for 48 h (or 96 h). When placing it, the graduated cylinder shall be placed in the middle of the oven and at least 75 mm from the bottom of the oven to ensure uniform heating.
- Note: When completing multiple tests within the same time period, adjust the positions of the graduated cylinders to avoid temperature changes in the oven caused by inappropriate convection. For the same reason, the number of tests completed at the same time should be limited.
- 7.3 After 48 h (or 96 h), remove the graduated cylinder from the oven and leave it at room temperature (21℃±3℃) for 1 h.
- 7.4 Observation and recording:
- 7.4.1 Oil separation amount [%(V/V)].
- 7.4.2 Water separation amount [%(V/V)].
- 7.5 Using a 10 mL pipette, withdraw the test sample according to the following steps:
- 7.5.1 Place the tip of the pipette accurately at the 80 mL mark of the graduated cylinder, slowly draw 10 mL of test sample, and transfer it to a narrow-mouth glass bottle of about 30 mL. The sample thus obtained is the upper test sample.
- 7.5.2 Place the tip of the pipette accurately at the 15 mL mark of the graduated cylinder, slowly draw 10 mL of test sample, and transfer it to a narrow-mouth glass bottle of about 30 mL. The sample thus obtained is the lower test sample.
- Note: If the water separation amount is equal to or exceeds 10%(V/V), then the determination of the lower-layer water content may be omitted.
- 7.6 Shake the narrow-mouth glass bottle of about 30 mL containing the test sample, take 0.5 μL of test sample with a microsyringe, and determine the water content [%(m/m)] of the upper and lower test samples in accordance with SH/T 0246.
9. Qualitative and quantitative determination and calculation formulas
- Determination items: oil separation amount [%(V/V)], water separation amount [%(V/V)], upper-layer water content [%(m/m)], lower-layer water content [%(m/m)].
- The determination of water content shall be carried out in accordance with SH/T 0246.
- Calculation formulas: not provided in the available source.
10. Precision
The precision of this standard depends on the degree of stability of the emulsion.
9.1 Type I — Stable emulsion
Note: A test sample whose water separation amount does not exceed 1%(V/V) after testing at 85℃ for 48 h or 96 h, and whose upper and lower layer water contents differ relatively little, with a ratio greater than 0.9.
Judge the reliability of the test results according to the following provisions (95% confidence level):
- 9.1.1 Repeatability: The difference between two results obtained by the same operator from repeated determinations shall not be greater than the value specified for repeatability in Table 1.
- 9.1.2 Reproducibility: The difference between two results submitted by different laboratories shall not be greater than the value specified for reproducibility in Table 1.
Table 1 Precision of Type I
| Item | Repeatability | Reproducibility |
|---|---|---|
| Oil separation amount, %(V/V) | 1 | 3 |
| Water separation amount, %(V/V) | 1 | 1 |
| Difference in the ratio of upper-layer to lower-layer water content, % | 10 | 14 |
Note: The above precision provisions were obtained from hydraulic fluids with water contents between 35%~50%(m/m) through statistical testing of interlaboratory test results.
9.2 Type II — Unstable emulsion
Note: A test sample whose water separation amount exceeds 10%(V/V) after testing at 85℃ for 48 h or 96 h. The precision limits of the 96 h test are the same as those in Table 1.
9.3 Type III — Marginal-stability emulsion
The change in the stability of the test sample varies with the treatment time or conditions or both, making the determination precision meaningless; therefore, no precision is specified. Note: A test sample whose water separation amount does not exceed 10%(V/V) after testing at 85℃ for 48 h or 96 h, but whose upper and lower layer water contents differ relatively greatly, with a ratio less than 0.9.
11. Report
- 8.1 Oil separation amount [%(V/V)].
- 8.2 Water separation amount [%(V/V)].
- 8.3 Upper-layer water content [%(m/m)].
- 8.4 Lower-layer water content [%(m/m)].
12. Referenced documents
- SH/T 0246 Determination of Water Content in Light Petroleum Products (Coulometric Method)
13. Source and verification
This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.
14. Quick Q&A reference
| Question | Key answer points |
|---|---|
| What does this standard apply to? | Water-in-oil emulsions. |
| What is the method summary? | Take a 100 mL test sample, keep it at constant temperature in an oven at 85℃±1℃ for 48 h or 96 h, and determine the oil separation amount, water separation amount, and upper and lower layer water contents. |
| What is the oven temperature control requirement? | 85℃±1℃, with forced air circulation. |
| What are the graduated cylinder specifications? | 100 mL, graduations 1 mL, with a ground-glass stopper, and the stopper has a vent groove. |
| What is the constant-temperature time? | 48 h or 96 h. |
| What is the position of the graduated cylinder in the oven? | Place it in the middle of the oven, at least 75 mm from the bottom of the oven. |
| How long should it stand at room temperature after the test? | Stand at room temperature (21℃±3℃) for 1 h. |
| Where is the upper test sample taken from? | At the 80 mL mark of the graduated cylinder, draw 10 mL. |
| Where is the lower test sample taken from? | At the 15 mL mark of the graduated cylinder, draw 10 mL. |
| Under what circumstances is the lower-layer water content not determined? | When the water separation amount is equal to or exceeds 10%(V/V). |
| According to which standard is the water content determined? | SH/T 0246. |
| What is the microsyringe sampling amount? | 0.5 μL. |
| Which items are reported? | Oil separation amount, water separation amount, upper-layer water content, lower-layer water content. |
| What is the definition of Type I? | After testing at 85℃ for 48 h or 96 h, the water separation amount does not exceed 1%(V/V), and the ratio of upper-layer to lower-layer water content is greater than 0.9. |
| What is the definition of Type II? | After testing at 85℃ for 48 h or 96 h, the water separation amount exceeds 10%(V/V). |
| What is the definition of Type III? | After testing at 85℃ for 48 h or 96 h, the water separation amount does not exceed 10%(V/V), but the ratio of upper-layer to lower-layer water content is less than 0.9. |
| Is precision specified for Type III? | No precision is specified. |
| What is the confidence level for precision? | 95%. |
| Which foreign standard is adopted by reference? | ASTM D3707-89. |
| Drafting organization? | Research Institute of Petroleum Processing. |
| Principal drafter? | Huo Cuijuan. |
Related public products
Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.
Search related productsSource and review status
This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.