SH/T 0635-1996 Sampling method for liquid petroleum products (semi-automatic method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

When fluid flows out from a thin-walled small hole, the linear velocity v (m/s) of the fluid flowing out of the thin-walled small hole and the height h (m) of the hole from the liquid surface conform to the relationship of formula (1):

v = f·√(2g·h) ……(1)

Where:

According to the above principle, a sampler is installed in the storage tank. The sampler can take equal amounts of sample at equal intervals, so that a representative sample can be collected from the sampling port at the bottom of the tank (Chapter 2).

4. Reagents and materials (purity / preparation)

not provided in the available source.

5. Instruments and equipment

5.1 Sampler (3.1)

Includes a sampling tube equipped with standard sampling holes, a sampling pump, and sampling valves, etc. (see Figure 1). Figure 1 Sampler schematic labels: 1- float; 2- sampling tube; 3- outlet valve; 4- inlet valve; 5- sampling valve; 6- sampling pump; 7- water sampling valve. Note 1): The sampler is supervised by the petroleum product standardization technical centralized unit and provided by Jinzhou Petrochemical Company Jinzhou Refinery.

5.2 Sample container (3.2)

Used to hold samples, the capacity is usually between 0.25~5 L, depending on the need. The sample container should not leak, be resistant to solvents, have sufficient strength, and have a suitable stopper. The following options are available:

5.3 Sample cooler (3.3)

It can be made by winding stainless steel tubing with an inner diameter of 6~8 mm. The outlet end of the coil is used to connect to the sample container, and the inlet end should be equipped with a flange or connected to other suitable devices of the sampling valve. When in use, the cooling coil can be immersed in a suitable cooling medium.

6. Recommended operating conditions

not provided in the available source (for sampling pump operating frequency see Section 8 5.3, 5.4).

7. Sampling and sample preparation

not provided in the available source (for sampling operation see Section 8).

8. Analytical procedure

8.1 Safety precautions (Chapter 4)

8.2 Operating method (Chapter 5)

9. Qualitative and quantitative and calculation formula

See Chapter 3 formula (1): v = f·√(2g·h). Where: f is the velocity coefficient of the fluid; g is the gravitational acceleration, m/s²; h is the height of the hole from the liquid surface, m; v is the linear velocity of the fluid flowing out of the thin-walled small hole, m/s. (In the original formula (1), the velocity coefficient symbol source-text extraction appears as "f", and the gravitational acceleration symbol source-text extraction appears as "『", requires confirmation against the source standard (source-text extraction).)

10. Precision

not provided in the available source.

11. Report

not provided in the available source.

12. Referenced documents

not provided in the available source.

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
What tank type does this standard apply to? Only applicable to vertical oil tanks (Chapter 1).
In which cases is it not applicable? Sampling from horizontal oil tanks, tank cars, oil tankers, and pipeline transportation (Chapter 1).
What is the sampling principle? The relationship between the linear velocity of outflow from a thin-walled small hole and the height of the hole from the liquid surface v=f·√(2g·h), the sampler takes equal amounts of sample at equal intervals (Chapter 2).
What parts does the sampler consist of? A sampling tube equipped with standard sampling holes, a sampling pump, and sampling valves, etc. (3.1).
What is the capacity range of the sample container? Usually 0.25~5 L, depending on the need (3.2).
In what case can a glass bottle not be used? Samples with a Reid vapor pressure greater than 180 kPa (3.2.1).
Can the oil can gasket be reused? It can only be used once (3.2.2).
What are the material and wall thickness requirements for plastic bottles? Uncolored polyethylene, wall thickness not less than 0.7 mm (3.2.3).
What are the specifications of the sample cooler? Made by winding stainless steel tubing with an inner diameter of 6~8 mm (3.3).
What is the sampling pump overhaul cycle? The pump body should be overhauled once a year (4.1).
Where should the operator stand when sampling? Stand on the upwind side (4.4).
What is the operation to form an "empty tube"? Inlet and outlet valves normally open, move the handle at a reciprocating frequency of more than 30 times per minute for more than 30 s (5.3).
How much oil head should be discharged? Discharge more than 100 mL, discard into a waste oil bottle (5.4).
How to operate at the end of sampling? Close the sampling valve, and at the same time stop moving the sampling pump (5.5).
Precision requirements? not provided in the available source.
Report requirements? not provided in the available source.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.