Origin Standard

SH/T 0706-2001 Determination of aluminum and silicon content in fuel oil (inductively coupled plasma emission spectrometry and atomic absorption spectrometry)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Take a certain amount of uniformly mixed sample in a platinum crucible, heat to carbonize the sample, then place it in a high-temperature furnace at 550℃±25℃ and heat to ash. The residue is melted with dilithium tetraborate and lithium fluoride, then digested with tartaric acid-hydrochloric acid solution, and finally diluted with water to a certain volume. Then introduce the test solution into the inductively coupled plasma emission torch, measure the emission light of the aluminum/silicon resonance line, and compare it with the emission light of the standard solution; or introduce the test solution into the flame of an atomic absorption spectrometer, measure the absorption of the aluminum/silicon resonance line, and compare it with the absorption of the resonance line of the standard solution.

4. Reagents and materials (purity / preparation)

All reagents used are analytical grade, and water shall meet the grade 2 water requirements of GB/T 6682.

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

7.2 Preparation of sample solution

7.3 Preparation of blank solution

In a 100 mL volumetric flask, add 0.4 g flux and 50 mL tartaric acid-hydrochloric acid mixed solution, dilute with water to 100 mL, then transfer to a 100 mL plastic bottle.

7.4 Preparation of standard calibration solutions

7.5 Determination of aluminum and silicon by inductively coupled plasma emission spectrometry

7.6 Determination of aluminum and silicon by atomic absorption spectrometry

9. Qualitative and quantitative determination and calculation formulas

Use formula (2) and formula (3) to respectively calculate the aluminum content X_Al (mg/kg) and silicon content X_Si (mg/kg) of the sample:

Where:

Expression of results: Whether using an inductively coupled plasma emission spectrometer or an atomic absorption spectrometer, the measured aluminum content and silicon content are accurate to 1 mg/kg.

10. Precision

Judge the reliability of the determination results according to the following rules (95% confidence level).

10.1 Inductively coupled plasma emission spectrometry

10.2 Atomic Absorption Spectrometry

11. Report

Take the arithmetic mean of the two results of repeated determinations as the determination result of the test sample.

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key points of answer
What does this standard apply to? Determination of aluminum and silicon content in fuel oils.
Determination range for aluminum? 5 mg/kg~150 mg/kg.
Determination range for silicon? 10 mg/kg~250 mg/kg.
What international standard is adopted? eqv ISO 10478:1994.
What is the method principle? After the test sample is carbonized, ashed, melted, and digested, aluminum/silicon is determined by ICP emission spectrometry or atomic absorption spectrometry.
What is the ashing temperature? 550℃±25℃.
Melting temperature and time? 925℃±25℃, first 5 min, then 10 min.
Flux composition? 90%(m/m) dilithium tetraborate + 10%(m/m) lithium fluoride.
Sample amount? 20 g~50 g, preferably containing about 1.3 mg aluminum.
Concentration points of aluminum standard calibration solutions? 5 mg/L, 10 mg/L, 25 mg/L, 50 mg/L.
Concentration points of silicon standard calibration solutions? 5 mg/L, 10 mg/L, 25 mg/L, 50 mg/L.
Wavelength for aluminum by atomic absorption? 309.3 nm.
Wavelength for silicon by atomic absorption? 251.6 nm.
Fuel gas/oxidant for atomic absorption? Acetylene/nitrous oxide.
To what precision is the result reported? 1 mg/kg.
How is the reported result taken? Take the arithmetic mean of the two results of repeated determinations.
Confidence level of precision? 95%.
Referenced water standard? GB/T 6682 Grade 2 water.
Storage container for sample solution? Plastic bottle (100 mL).
After how many samples must calibration be performed? After every five samples, calibrate once with the standard calibration solution.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.