Origin Standard

SH/T 0731-2004 Determination of Evaporation Loss of Lubricating Oils (Thermogravimetric Noack Method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / supersession relationship

2. Scope of application and non-applicability

3. Method principle

Place the lubricating oil sample on the sample pan of a suitable thermogravimetric analyzer (TGA), place the sample pan on the sample holder, and rapidly heat to 247~249°C in an air flow, then hold at constant temperature for a period of time. Throughout the process, the thermogravimetric analyzer monitors and records the mass lost by the sample due to evaporation. The thermogravimetric Noack evaporation loss is the mass loss fraction corresponding to the Noack reference time determined for the sample under the same thermogravimetric conditions on the subsequently determined curve of sample mass loss fraction versus time (thermogravimetric curve). (Chapter 4)

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

11. Report

12. Referenced Documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key Answer Points
What is the method number and name of this standard? SH/T 0731-2004 Determination of Evaporation Loss of Lubricating Oils (Thermogravimetric Noack Method)
Adoption relationship? Modified adoption of ASTM D6375-99a, redrafted according to it
Publication and implementation dates? Published on 2004-04-09, implemented on 2004-09-01
Scope of application? Base oils and additive-containing lubricating oils with Noack evaporation loss 0%~30%
Method principle? TGA The sample pan is rapidly heated to 247~249°C in an air flow and held at constant temperature, and the mass loss is recorded; the mass loss fraction corresponding to the Noack reference time is taken as the result
How is the sample mass determined? M₀ = 350(ID)², where ID is the average inner diameter of 10 sample pans (cm), accurate to 1mg
Sample pan specifications? Cylindrical type, ratio of inner diameter to height not less than 0.45, volume 50µL±3µL
Temperature control accuracy requirement of the thermogravimetric analyzer? Less than 0.5°C
Temperature range of temperature calibration standard substances? Should include 250°C
Burn purification conditions? Air flow 200–500mL/min, raise temperature to at least 800°C, maintain until no smoke is emitted, usually 15–20min
Frequency of Noack reference time determination? Complete every day before evaluating samples
Precision of Noack reference time? As accurate as possible to 0.01min
How is the constant temperature time adjusted? Can be modified to the Noack reference time plus 2min
By how much must the reference time differ from previous determinations to require inspection? When it exceeds 10%, inspect the thermogravimetric analyzer operation according to Chapter 8
Precision of result reporting? Accurate to 0.01%
Repeatability formula? r = 0.31(X)^0.6 (exponent requires confirmation against the source standard (source-text extraction))
Reproducibility formula? R = 0.39(X)^0.6 (exponent requires confirmation against the source standard (source-text extraction))
Relationship with the results of the standard Noack method? There is no significant difference between the results determined by this method and the Noack evaporation loss results determined by the SH/T 0059 method
What are the referenced documents? SH/T 0059-96, ASTM E1582, ASTM D6375-99a