Origin Standard

SH/T 0750-2005 Determination of high-temperature oxidative deposits in engine oils (thermal oxidation simulation test method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After an engine oil sample containing iron naphthenate is heated to 100℃ and contacted with nitrous oxide (NO) and wet air, it passes through a weighed deposition rod at a certain pump speed. The temperature of the deposition rod changes periodically between 200℃ and 480℃, and the entire test undergoes 12 cycles, with each cycle lasting 9min 30s. After the 12 cycles end, the deposition rod is cleaned and dried to obtain the mass of rod deposits. The sample released in the system flows through a weighed filter. The sum of the rod deposits and the filter deposits is the mass of total deposits.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

Judge the reliability of the test results according to the following rules (95% confidence level).

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference for Questions and Answers

Question Key Answer Points
Standard number and title? SH/T 0750—2005 Determination of High-Temperature Oxidation Deposits of Engine Oils (Thermal Oxidation Simulation Test Method)
Adoption relationship? Modified adoption of ASTM D6335-98
Method abbreviation? TEOST
Applicable deposit range? Interlaboratory study: total deposit 10mg–65mg; operating experience: 2mg–180mg
What is added to the test sample? Iron naphthenate solution, so that the iron content is about 100 mg/kg
Reaction chamber temperature? 100℃ (when pouring in the test sample 100℃±5℃)
Deposit rod temperature range? 200℃~480℃ periodic variation
Number of cycles and time? 12 cycles, each cycle 9min 30s
Total test time? 1h54min
Gas flow rate? Both wet air and NO are 3.5mL/min
Liquid flow rate? 0.49mL/min (0.40g/min)
How many categories of deposits? Rod deposit, filter deposit, total deposit
Calculation formulas? m₁=A−B; m₂=C−D; m=m₁+m₂
Reporting precision? To the nearest 0.1mg
Precision formulas? r=3.058×X^0.33; R=4.774×X^0.38 (requires confirmation against the source standard (source-text extraction))
Calibration interval? Pump speed calibration is recommended once every three months 1; instrument verification at least once every three months 1
Reference oils? CG-1 (20mg–30mg), CF-1 (50mg–60mg), TPC calibration oil
Normative appendices? Appendix A pump speed calibration, Appendix B thermocouple depth determination, Appendix C power adjustment

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.