Origin Standard

SH/T 0787-2006 Determination of wear characteristics of petroleum-based hydraulic oils by high-pressure vane pump

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English name / supersession relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and specimen preparation

8. Analysis procedure

9. Qualitative and quantitative and calculation formulas

10. Precision

11. Report

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
Standard number and name? SH/T 0787—2006 Determination of wear characteristics of petroleum-based hydraulic oil high-pressure vane pumps
Adoption relationship? Modified adoption of ASTM D6973-05
Issue/implementation dates? Issued on 2006-05-12, implemented on 2006-11-01
Method summary? 190L±4L The test oil is circulated through a rotary vane pump for 50h, and the anti-wear property is evaluated by the mass loss of the stator and all blades (mg)
Test pump model? Vickers 35VQ25A-11*20 (replaceable-cartridge rotary inner vane pump)
Test oil amount? 400L (the test requires 3 test pumps, with no oil or filter change in between)
Test oil viscosity requirement? Not lower than viscosity grade ISO32 or viscosity grade SAE10W
Test operating conditions? Rotational speed 2400r/min±20r/min, outlet pressure 20.7MPa±0.2MPa, inlet temperature 95℃±3℃, operation 49h
Minimum pump flow? 132.5L/min; if lower, stop the test
Cleanliness requirement? Before the formal test, at least reach level GB/T 14039 18/16/13, and particle counting shall satisfy GB/T 18854
Weighing accuracy? 0.001g (stator and ten blades, excluding inner blades; blades must be demagnetized before weighing)
Number of test pumps and duration? 3 test pumps each run for 50h
Report content? Mass loss of stator and blades (0.001g), start and end flow rates, abnormal wear observations, start and end cleanliness
Precision? Not provided in the available source (the main text of Chapter 14 is missing and requires confirmation against the source standard (source-text extraction))
Water-based synthetic fluid conditions? See normative Appendix A; the upper limits of inlet temperature are 43℃±3℃, 54℃±3℃, 65℃±3℃ respectively, and the minimum flow is 132.5L/min
Normative references? GB 1922—1980, GB/T 14039, GB/T 17489, GB/T 18854

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.