SH/T 0794-2007 Determination of vapor pressure of petroleum products — Micro method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full title / English title / replacement relationship

2. Scope of application and non-applicability

3. Method principle

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical Procedure

9. Qualitative and Quantitative and Calculation Formulas

10. Precision

11. Report

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A reference

Question Key answer points
Standard number and title? SH/T 0794—2007 Determination of vapor pressure of petroleum products — Micro method
Adoption relationship? Modified adoption of ASTM D5191-04a
Applicable vapor pressure range? Under the conditions of 37.8℃ and vapor-liquid ratio 4:1, 7 kPa~130 kPa
Applicable samples? Air-containing volatile liquid petroleum products with boiling point above 0℃; excluding crude oil (not included in the precision study)
Sample amount? 1 mL~10 mL
Test temperature? 37.8℃±0.1℃
Vapor-liquid ratio? 4:1 (the test chamber volume is 5 times the sample volume)
Sample cooling temperature? 0℃~1℃
Syringe cooling temperature? 0℃~4.5℃
Sample container fill amount? 70%~80% of the container volume; for arbitration testing, a 1 L container must be used
Air saturation procedure? Open the lid, reseal, shake vigorously, return to the cold bath or refrigerator for at least 2 min, repeat at least 2 times
How to handle turbid samples? May be analyzed; after reporting the result, append the letter H; precision and bias have not been determined
How to handle samples with phase separation? Discard the test and the sample
DVPE Calculation formula? DVPE = (0.965X) − A, A = 3.78 kPa, X is the total vapor pressure
Result reporting precision? Precise to 0.1 kPa, no need to indicate temperature
Pressure sensor calibration interval? At least once every six months, or at shorter intervals according to quality control checks
Thermometer verification interval? At least once every six months
Quality control check frequency? Calibrate the instrument daily with a defined liquid of known volatility
Repeatability formula? r = 0.00807 (DVPE + B), the value of B requires confirmation against the source standard (source-text extraction)
Reproducibility formula? R = 0.0161 (DVPE + B), the value of B requires confirmation against the source standard (source-text extraction)
Referenced method standards? GB/T 4756, GB/T 9168, ASTM D4953, ASTM D5190
Time limit from opening the lid to completing injection? Not more than 1 min
Criterion for stable pressure reading? Three consecutive readings vary by no more than 0.1 kPa

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.