SH/T 0100-1991 Determination of Solidification Point of Petroleum Wax

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

At room temperature, place the 50mg wax sample in a test tube and heat it above the solidification point of the sample. Then insert the thermocouple probe connected to the recorder into the sample. As the wax sample cools at room temperature, the thermocouple response curve of the cooling wax is immediately drawn on the recorder chart. The temperature at which the first significant change in the slope of the curve appears is the solidification point. (Chapter 4 Method summary)

Definition (Chapter 3): Solidification point of petroleum wax — the temperature at which the first significant change in the slope of the wax cooling curve appears when the sample changes from liquid to solid.

4. Reagents and materials (purity / preparation)

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

Appendix A Calibration of recorder standard curve (supplementary document):

9. Qualitative and quantitative determination and calculation formulas

10. Precision

Precision table (℃):

Sample type Repeatability allowable error Reproducibility allowable error
Paraffin wax 0.6 1.2
Microcrystalline wax 0.7 2.4

11. Report

Take the arithmetic mean of the two results of duplicate determination as the test result, read to 0.1℃. (Chapter 8)

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer points
What samples does this standard apply to? Paraffin wax and microcrystalline wax (Chapter 1)
What is the definition of solidification point? The temperature at which the first significant change in the slope of the wax cooling curve appears when the sample changes from liquid to solid (Chapter 3)
What is the sample amount? 50mg±5mg; for some microcrystalline waxes when the slope shows no obvious change, increase to 100—150mg (6.2, 6.5.1)
What thermocouple is used? Iron—constantan or nickel-chromium—nickel-silicon, sheathed two-core grounded-junction type, diameter 1.0mm, length 500.0mm; in special cases for microcrystalline wax, use a thermocouple formed by welding the two thermocouple wires together (diameter about 0.8mm) (5.1, 6.5.1)
What is the recorder paper speed requirement? 10—20mm/min (5.2.4)
Aluminum heating block heating voltage? Paraffin wax 110—130V; microcrystalline wax 140—160V (6.4)
To what temperature is the sample heated? Above the expected solidification point 10—15℃ (6.5)
How often is the recorder standard curve calibrated? When used frequently, calibrate at least every 60d (6.1)
How is the result expressed? Take the arithmetic mean of the two results of duplicate determination, read to 0.1℃ (Chapter 8)
What is the precision for paraffin wax? Repeatability 0.6℃, reproducibility 1.2℃ (Chapter 7 precision table)
What is the precision for microcrystalline wax? Repeatability 0.7℃, reproducibility 2.4℃ (Chapter 7 precision table)
Which foreign standard is adopted by reference? ASTM D3944-80(85) "Determination of Solidification Point of Petroleum Wax" (additional notes)
What are the referenced standards? GB/T 8026 Determination of Drop Melting Point of Petroleum Wax and Petrolatum (Chapter 2)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.