SH/T 0196-1992 Determination of Oxidation Stability of Lubricating Oils

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After the sample undergoes mild oxidation under specified conditions (one steel ball and one copper ball each, with continuous introduction of air 4h), its water-soluble acid is measured. After deep oxidation (low-carbon steel spiral coil, copper sheet, with continuous introduction of oxygen 8h), its acid value and sediment are measured.

4. Reagents and materials (purity / preparation)

4.1 Materials

4.2 Reagents

4.3 Solution preparation in preparatory work

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

8.1 Determination of water-soluble acid content formed after mild oxidation of lubricating oil

8.2 Determination of the sediment content and acid value formed after deep oxidation of lubricating oil

8.3 Cleaning of oxidation tubes and treatment of metal parts (preparatory work)

9. Qualitative and quantitative determination and calculation formulas

9.1 Non-volatile water-soluble acid content after oxidation X₁ (mgKOH/g) is calculated according to formula (1):

X₁ = (V − V₁/3) × c₁ × 0.0561 × 1.25 / 25 × n × 3 = 0.002805 (V − V₁) × n × c₁

9.2 Volatile water-soluble acid content after oxidation X₂ (mgKOH/g) is calculated according to formula (2):

X₂ = (V₂ − V₁) × c₁ × 0.0561 × 1.25 / 30 = 0.002338 (V₂ − V₁) × c₁

9.3 Sediment content after oxidation X₃ [%(m/m)] is calculated according to formula (3):

X₃ = m₁ / M × 100

9.4 Acid value after oxidation X₄ (mgKOH/g) is calculated according to formula (4):

X₄ = (V₃ − V₀) × c₂ × 0.0561 × n₁ / m

10. Precision

11. Report

For the content of non-volatile water-soluble acids, the content of volatile water-soluble acids, the precipitate content, and the acid value of the sample after oxidation, the arithmetic mean of two results of repeated determinations shall be taken as the determination result.

12. Normative references

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick-reference Q&A

Question Key points of the answer
What does this standard apply to? It applies to lubricating oils.
What is the summary of the method? After mild oxidation (one steel ball and one copper ball each, with air passed through 4h), determine water-soluble acids; after deep oxidation (low-carbon steel spiral coil, copper sheet, with oxygen passed through 8h), determine acid value and precipitate.
Mild oxidation temperature, air flow rate, time? 125℃±0.5℃, air per minute 50mL, continuous 4h.
Deep oxidation temperature, oxygen flow rate, time? 125℃±0.5℃, oxygen per minute 200mL, continuous 8h.
Sample amount for mild oxidation? 30g, accurate to 0.1g.
Sample amount for deep oxidation? 30g, accurate to 0.1g.
Sample weight of oxidized oil for water-soluble acid determination? 25g, accurate to 0.1g.
Sampling amount of oxidized oil for precipitate and acid value determination? 20~25g, accurate to 0.01g.
Standing conditions for precipitate? Stand in the dark at 20℃±3℃ for 12h.
Drying conditions for precipitate? Dry at 105℃±3℃ to constant weight; the difference between two consecutive weighings shall not exceed 0.0004g.
What standard solution is used to titrate water-soluble acids? c(KOH)=0.025mol/L potassium hydroxide standard titration solution.
What standard solution is used to titrate acid value? c(KOH)=0.05mol/L potassium hydroxide-ethanol standard titration solution.
Indicator for acid value titration? Alkali blue 6B ethanol indicator solution (20g/L).
Indicator for checking water-soluble acids? Methyl orange indicator solution (1g/L) to check neutrality; phenolphthalein indicator solution (10g/L) for titration.
Precision requirements? Repeatability of water-soluble acid content shall not exceed 0.002mgKOH/g; precipitate and acid value are 5% of the arithmetic mean.
How many results are taken for the report? The arithmetic mean of two results of repeated determinations for each.
Which standards are cited? GB/T 8021, SH 0004.
What standard does it replace? It replaces zB E34 014-88.
What standard is referenced and adopted? Soviet national standard GOST 981-52.