Origin Standard

SH/T 0578-1994 Emulsion pH value determination method

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

The emulsion sample is placed in a 100mL beaker, and its pH value is determined with a pH meter.

4. Reagents and materials (purity / preparation)

Unless otherwise specified, all reagents used in the test are of analytical grade; whenever water is involved, distilled water or water of equivalent purity shall be used. At a temperature of 20℃, the pH value of distilled water shall be 6.0~7.0.

Preparation of buffer solutions:

5. Instruments and equipment

6. Recommended operating conditions

Temperature, ℃ Potassium hydrogen phthalate Potassium dihydrogen phosphate Disodium hydrogen phosphate Sodium tetraborate
5 4.00 not provided in the available source 6.95 9.39
10 4.10 (requires confirmation against the source standard (source-text extraction)) not provided in the available source 6.92 9.33
15 4.00 not provided in the available source 6.90 9.28
20 4.00 not provided in the available source 6.88 9.23
25 4.00 not provided in the available source 6.86 9.18
30 4.01 not provided in the available source 6.85 9.14
35 4.02 not provided in the available source 6.84 9.10
40 4.03 not provided in the available source 6.84 9.07
45 4.04 not provided in the available source 6.83 9.04

7. Sampling and sample preparation

5.1 Preparation of emulsion sample: in a 100mL beaker, weigh 49g (or 47.5g) distilled water, then weigh in 1g (or 2.5g) soluble oil. Prepare an emulsion sample with a concentration of 2% (m/m) or 5% (m/m), for use in determining its pH value.

8. Analytical procedure

Preparation of the electrode system:

9. Qualitative and quantitative determination and calculation formula

not provided in the available source (this standard is for direct determination of the pH value, and there is no calculation formula).

10. Precision

Judge the reliability of the results according to the following provisions (95% confidence level):

11. Report

Take the arithmetic mean of two results from repeated determination as the pH value of the sample (the result shall be taken to one decimal place).

12. Referenced documents

not provided in the available source.

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference Q&A

Question Key points of answer
What does this standard apply to? Emulsions for metalworking.
What is the method summary? The emulsion sample is placed in a 100mL beaker, and its pH value is determined with a pH meter.
What is the accuracy requirement for the pH meter? 0.1pH.
What electrodes are used? Glass electrode type 231, calomel electrode type 232.
How is the sample concentration prepared? 2% (m/m) or 5% (m/m) emulsion sample.
How much is weighed for sample preparation? Weigh 49g (or 47.5g) distilled water, then weigh in 1g (or 2.5g) soluble oil.
How many buffer solutions are there? Three: pH 4.01, pH 6.88, pH 9.22.
What is the stabilization time for instrument calibration? Turn on the power of the pH meter, stabilize for 30min.
What is the criterion for passing calibration? The difference between the displayed value in another buffer solution and the pH value of the buffer solution is within the 0.05pH value.
What is the repeatability requirement? The difference between two results obtained by repeated determination by the same operator shall not be greater than the 0.2pH value.
What is the reproducibility requirement? The difference between two results submitted by different laboratories shall not be greater than the 0.5pH value.
How is the reported result taken? Take the arithmetic mean of two results from repeated determination, and take the result to one decimal place.
What is the pH requirement for distilled water? At 20℃, the pH value of distilled water shall be 6.0~7.0.
How is a new glass electrode handled? It shall be soaked in distilled water for 24h before use.
How is electrode contamination handled? After continuous use for one week, if the surface of the electrode bulb is contaminated, the electrode bulb may be soaked in cold chromic acid cleaning solution for 30s, then rinsed clean with distilled water, and then soaked in distilled water for later use.

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.