SH/T 0060-1991 Determination of oxygen absorption of rust-preventive grease (oxygen bomb method)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

The sample is oxidized in an oxygen bomb heated to 99℃ and filled with 760kPa (7.7kgf/cm², original text is "7.7kgf/cm?", requires confirmation against the source standard (source-text extraction)) oxygen, and the pressure is observed and recorded at specified time intervals. After 100h, the corresponding decrease in oxygen pressure represents the degree of oxygen absorption of the sample.

4. Reagents and materials (purity / preparation)

5. Apparatus and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

Subtract the oxygen pressure (gauge pressure) after the 100h test from the oxygen pressure (gauge pressure) after immersing the oxygen bomb in the oil bath for 2h; this is the degree of oxygen absorption, expressed in units of kPa.

10. Precision

not provided in the available source.

11. Report

Take the arithmetic mean of the pressure drops (kPa) from two oxygen bomb tests as the test result.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick reference Q&A

Question Key answer points
What does this standard apply to? Rust-preventive grease, rust-preventive lubricating grease.
What is the method principle? Oxidation in oxygen at 99℃, 760kPa; after 100h, the degree of oxygen absorption is represented by the decrease in oxygen pressure.
What is the sample amount? Molten sample 4.00g±0.01g.
How many sample dishes/small brass discs are used? 10 sample dishes, 10 small brass discs.
What is the oxygen purity requirement? Not lower than 99.5%.
How is the oxygen bomb treated before oxygen filling? Fill with oxygen to 690kPa then discharge, repeat four times, after the fifth time to 690kPa close the needle valve and check for leakage.
What is the oil bath temperature requirement? 99℃±0.5℃, temperature gradient less than 0.5℃.
What is the pressure stabilization requirement? Stabilize at 760kPa±5kPa, maintain for at least 2h.
How long is the test? 100h.
What is the pressure recording frequency? Observe and record at least every 24h.
How is the result calculated? Gauge pressure after 2h minus gauge pressure after 100h, unit kPa.
What value is taken for the final report? Arithmetic mean of the pressure drops from two oxygen bomb tests.
After how long must the small brass discs be re-polished? After more than 24h.
Which foreign standard is referenced and adopted? JIS K 2246—89 "Rust Preventive Oil" clause 5.18.
What are the referenced standards? GB 5232, SH 0004.