Origin Standard

SH/T 0069-1991 Determination of pH value of engine antifreeze, rust inhibitor and coolant

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

Measure 100 mL of sample, inject into 150 mL beaker, use pH meter to determine its pH value. Note: When determining the pH value of a concentrated product, according to the general concept the meter reading is not the measured pH value, but the apparent pH value, which is very useful when analyzing product condition.

4. Reagents and materials (purity / preparation)

Unless otherwise specified, all test reagents are of analytical grade; whenever water is involved, distilled water or water of equivalent purity shall be used. At 25℃, the pH value of distilled water should be 6.2~7.2 (the source says "6.2[unreadable separator]7.20", requires confirmation against the source standard (source-text extraction)).

Reagents:

Buffer solution preparation:

Materials:

5. Instruments and equipment

6. Recommended operating conditions

7. Sampling and sample preparation

8. Analytical procedure

9. Qualitative and quantitative determination and calculation formula

not provided in the available source (this standard is direct instrumental determination, no calculation formula).

10. Precision

11. Report

Take the arithmetic mean of the two results of repeated determination as the test result, and take it to 0.1 pH value.

12. Referenced documents

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Q&A

Question Key answer
What does this standard apply to? Concentrates of engine antifreeze, rust inhibitor and coolant, and water dilutions of these product concentrates, whether used or unused
What is it not applicable to? Solid rust inhibitors
What is the sampling amount? 100 mL, inject into 150 mL beaker
Stirring time? 3~5 min, to bring the system to equilibrium
Precision requirement of the pH meter? 0.1 pH value
What electrodes are used? Glass electrode 231 type, calomel electrode 232 type
According to which standard are sampling and dilution carried out? SH/T 0065
Recommended dilution concentration? Engine coolant and antifreeze are 50% (V/V) or 33% (V/V); the concentration of the rust inhibitor solution should be within the use range
How many buffer solutions are there? 4 types: pH 4.01, 6.86, 9.18, 11.72
Allowable deviation for buffer solution calibration? The difference between the readings of the two buffer solutions is within 0.05 pH value, otherwise replace the electrode and recalibrate
Repeatability requirement? The difference between two results by the same operator should not be greater than 0.1 pH value
Reproducibility requirement? The difference between two results from different laboratories should not be greater than 0.2 pH value
How is the result reported? Take the arithmetic mean of two duplicate determination results, rounded to the 0.1 pH value
How should a glass electrode with an oil film be treated? Clean with a mixed solvent of 1:1 (V/V) toluene and ethyl acetate
What special provisions apply to silicate-containing antifreeze? After preparing the dilution, test immediately and record; after standing for 30 min, record again; the latter is lower than the direct test by the 0.2 pH value; after dilution, the 24 h determination is lower than the direct test by 0.3 to 0.5 pH value
Which foreign standard is referenced and adopted? ASTM D1287-85

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.