Origin Standard

SH/T 0796-2007 B-100 Determination of free glycerol and total glycerol content in biodiesel fatty acid methyl esters (gas chromatography)

AI-translated method card — human verification pending. This is not an official translation of the standard. Unclear source values remain unverified; check the original standard and product certificate before use.

Card type: Test method

1. Method number / full name / English name / replacement relationship

2. Scope of application and non-applicability

3. Method principle

After the sample is silylated with N-methyl-N-trimethylsilyl trifluoroacetamide (MSTFA), it is analyzed by gas chromatography. The quantification process uses dual internal standards and four reference substances to correct the results. For the determination of mono-fatty acid glycerides, di-fatty acid glycerides and tri-fatty acid glycerides, glyceryl monooleate, glyceryl dioleate and glyceryl trioleate are used as standard reference substances, respectively. The average conversion factor is used to calculate the content of bound glycerol in the test sample (Chapter 4).

4. Reagents and materials (purity / preparation)

Preparation of calibration standards (9.1): prepare the standards as listed in Table 2, weigh the pure components in a volumetric flask to an accuracy of 0.1 mg, dilute to the mark with pyridine, and store the prepared standard solutions in a refrigerator for later use.

Table 2 Stock solutions of each component (the source table header and part of the content have severe source-text extraction noise; the following is the identifiable content, requires confirmation against the source standard (source-text extraction)):

Compound CAS number Weighed mass mg Dilution volume mL
Glycerol 56-81-5 25 50
Glyceryl monooleate 111-03-5 50 10
Glyceryl dioleate 2465-32-9 50 10
Glyceryl trioleate 122-32-7 50 25
1,2,4-butanetriol (internal standard 1) 820-36-6 25 10
n-Pentadecane (alternative internal standard 1) 621-7-6 (requires confirmation against the source standard (source-text extraction)) 20 10
Glyceryl tridecanoate (internal standard 2) not provided in the available source 80 not provided in the available source

Preparation of mixed standards (9.2): according to the amounts listed in Table 3, use a microsyringe or pipette to transfer the specified volumes of calibration standards into 10 mL capped sample bottles to prepare five mixed standard solutions. To each of the five standard solutions, respectively add 100 μL MSTFA, cap the bottles and shake, allow to stand at room temperature for 15 min~20 min, add about 8 mL n-heptane, shake well and set aside.

Table 3 Standard solutions (volume unit: μL, source-text extraction severe noise, requires confirmation against the source standard (source-text extraction)):

Standard solution number 1 2 3 4 5
Glycerol volume 10 30 70 100 not provided in the available source
Monoglyceride volume 20 50 160 (requires confirmation) 150 (requires confirmation) 200
Glyceryl dioleate volume 30 40 (requires confirmation) 70 100 not provided in the available source
Glyceryl trioleate volume 10 20 40 (requires confirmation) 70 100
1,2,4-butanetriol 100 100 100 100 100
n-Pentadecane 100 100 100 100 100
Glyceryl tridecanoate 100 100 100 100 100

5. Instruments and equipment

6. Recommended operating conditions

Table 1 Chromatographic analysis conditions (source-text extraction severe noise, requires confirmation against the source standard (source-text extraction)):

Condition Condition 1 Condition 2
Injection port Cold on-column injection port Cold on-column injection port
Injection volume 1 μL 1 μL
Column temperature program - initial temperature 50℃ hold 1 min 70℃ hold 1 min
First stage Heating rate 15℃/min to 180℃ Heating rate 15℃/min to 190℃
Second stage Heating rate 7℃/min to 230℃ Heating rate 7℃/min to 260℃
Third stage Heating rate 30℃/min to 380℃, hold 10 min Heating rate 30℃/min to 380℃, hold 10 min
Detector Flame ionization detector (FID) Flame ionization detector (FID)
Detector temperature 380℃ 380℃
Carrier gas type Nitrogen or helium (the source text writes "nitrogen or hydrogen", requires confirmation against the source standard (source-text extraction)) Nitrogen
Flow rate 3 mL/min (at 50℃) 2 mL/min (at 50℃)

7. Sampling and test sample preparation

8. Analysis procedure

Table 4 Relative retention times of components:

Compound Internal standard used Relative retention time
Glycerol 1,2,4-butanetriol (internal standard 1) 0.85 (0.71*)
1,2,4-butanetriol (internal standard 1) — 1.00
n-Pentadecane (alternative internal standard 1) — 1.00
Monopalmitin Tridecanoin (internal standard 2) 0.76
Monoolein, monolinolein, monolinolenin, monostearin Tridecanoin (internal standard 2) 0.83~0.86
Tridecanoin (internal standard 2) — 1.00
Di-fatty acid glycerides — 1.05~1.09
Tri-fatty acid glycerides — 1.16~1.31

*When n-pentadecane is used as the internal standard, the relative retention time of glycerol is 0.71.

Figure 1 Typical chromatogram (peak assignments): 1—glycerol; 2—1,2,4-butanetriol (internal standard 1); 3—n-pentadecane (alternative internal standard 1); 4—C14fatty acid methyl ester; 5—C16fatty acid methyl ester; 6—C18fatty acid methyl ester; 7—C18fatty acid methyl ester (original text reads "Gz", requires confirmation against the source standard (source-text extraction)); 8—C18mono-fatty acid glycerides; 9—C18fatty acid methyl ester (original text reads "Gaa", requires confirmation against the source standard (source-text extraction)); 10—C18mono-fatty acid (a.stearic acid; b.oleic acid, linoleic acid, linolenic acid) glycerides; 11—tridecanoin; 12—di-fatty acid glycerides (carbon numbers: 34, 36, 38); 13—tri-fatty acid glycerides (carbon numbers: 52, 54, 56, 58).

9. Qualitative and Quantitative Calculation Formulas

10. Precision

Table 5 Repeatability:

Component Repeatability, % (mass fraction)
Free glycerol 0.001
Mono-fatty acid glycerides 0.021
Di-fatty acid glycerides 0.021
Tri-fatty acid glycerides 0.032
Bound glycerol 0.008
Total glycerol 0.009

11. Report

12. Normative References

13. Source and verification

This page is an AI translation of the available Chinese method card. Human verification is pending. It is not an official translation of the standard. Check the source standard and product certificate before use.

14. Quick Reference Q&A

Question Key Answer Points
Detection range for free glycerol? 0.005%~0.05% (mass fraction) (1.1)
Detection range for total glycerol? 0.05%~0.5% (mass fraction) (1.1)
What raw materials is it not applicable to? Biodiesel synthesized from vegetable oils containing relatively more lauric acid glycerides (such as coconut oil, palm kernel oil) (1.1)
What is the silylating reagent? MSTFA (N-methyl-N-trimethylsilyltrifluoroacetamide) (Chapter 4, 7.3)
Quantification method? Dual internal standards and calibration with four reference substances (Chapter 4)
What reference substances are used for mono-/di-/tri-fatty acid glycerides respectively? Monoolein, diolein, triolein (Chapter 4)
How is bound glycerol calculated? Calculated using the average conversion factor (Chapter 4); GLm=0.2591×monoester, GLd=0.1488×diester, GLt=0.1044×triester (11.1.3)
How is total glycerol calculated? Free glycerol mass fraction + bound glycerol mass fraction (equation 9)
What is internal standard 1? 1,2,4-butanetriol (Table 2, Table 4)
What is internal standard 2? Tridecanoin (Table 2, Table 4)
What is the alternative internal standard? n-Pentadecane (Table 2, Table 4)
Correlation coefficient requirement? r² no less than 0.99 (9.4.2)
Reporting precision? Accurate to 0.001% (mass fraction) (11.2)
Repeatability for free glycerol? 0.001% (mass fraction) (Table 5)
Repeatability for total glycerol? 0.009% (mass fraction) (Table 5)
Is the deviation confirmed? Not confirmed, because there is no reference material (12.2)
Detector type? Flame ionization detector (FID) (Table 1)
Detector temperature? 380℃ (Table 1)
Injection volume? 1 μL (Table 1)
Column specifications? Column length 10 m or 15 m, internal diameter 0.32 mm, film thickness 0.1 μm (6.1.2)

Related public products

Method references do not confirm that a product is suitable for this edition. Check its certificate and availability.

Search related products

Source and review status

This translation has not received a complete independent technical review. Missing sections and unclear source values remain identified above.